  1. Runis

    Digital Extension BLOKED

    Hi!! I have the same problem as Astonces in BC12/SP5, hope you can help me too. <SACOP:LIM=2,UNIT=DER,DSOFF=9,FILNO=2,POINT=390; MEMORY CONTENT ON INDIVIDUAL POSITION EXE A FILE NUMBER RELOAD FILE START DS FILE START 2 0001F4C6 POINT RELOFF DSOFF...
  2. Runis

    TLU79 configuration for AXE in BC12

    Hey, it works now!!!!!!!! Thank you very very much... I have compared your ROCAI with mine, and changing bit a bit, I have found that it was the las digit of the SEL which was making my route go wrong (it´s about "route to telident machine for emergency calls"). Thanks a lot,
  3. Runis

    TLU79 configuration for AXE in BC12

    I already tried that one, and it does not work either. What about ROCAI??? Thanks for your help,
  4. Runis

    TLU79 configuration for AXE in BC12

    Yes, that is what my service provider says... Thanks,
  5. Runis

    TLU79 configuration for AXE in BC12

    Sorry whosrdaddy, It does not work. The link is IDLE/FREE, I can dial the whole number, but after a while in silence, I get the three tones that indicate the call is aborted. I tried with different ROCAI/RODAI configurations but there is no way. I must be missing something!!!!!! Thanks for...
  6. Runis

    TLU79 configuration for AXE in BC12

    Hi, I am upgrading my system from BC9 to BC12.1. Everything is working fine, but in BC12.1 I cannot make outgoing calls through a 2B+D route I had configured for AXE public system. I guess it´s a configuration problem, as it worked fine in BC9 and it does no longer work in BC12... My route...
  7. Runis

    Problem with incoming calls in CIL

    <CLFOP:FORM=5; OUTPUT FORMAT DATA FORM DATA 1 2 3 4 5 6 7 8 9 10 5 3M 4J 4P 1M 5K 1M 4N 1M 2I 1M 5A 5C 1M 20G 1M 10E 1M 15D 1M 6F 1M 3S 1M 2R 1M 2O 1M 6T...
  8. Runis

    Problem with incoming calls in CIL

    Sorry, I thought we were using FORM 2, but it´s FORM 5 actually... CLINP site A: CLINP; CALL LOGGING DATA CALL LOGGING MODE: ACTIVATED HEADER FORM DMPSIZ DISCR IN SERVICE LOGABN SMDR01 5 1 0 YES...
  9. Runis

    Problem with incoming calls in CIL

    Hi, I have two systems in BC10 Rev.B linked through Q-SIG union; incoming calls to any extension enter to either system A or B ISDN PRIs, and are distributed from A to B through the Q-SIG link. The problem is that the charging is not ok for those incoming calls to system A that end in system...
  10. Runis

    QSIG BC12-BC12

    Thanks whosrdaddy, I tried with VARI 15440000 and works ok!!!!!!!!!!!! :-) Thanks for your help, Runis.
  11. Runis

    QSIG BC12-BC12

    Hi, I am trying to set up a Q-SIG between two MD110 BC12 SP5, but internal follow me (*21*6XXX#) does not work through the Q-SIG (it does internally). I can make calls and call back works fine. My route is: SIDE A: <RODAP:ROU=90; ROUTE DATA ROU TYPE VARC VARI VARO...
  12. Runis

    Onebox 3.0 Transfer to Operator

    Hi everyone, When a OneBox user does not have a personal greeting recorded and a call is forwarded to the Telephony Server on a RNA (Ring No Answer), the following message is played: "I'm sorry, extension XXXX does not answer. At the tone begin recording your message. To stop recording press...
  13. Runis

    Silent Intrusion in BC9

    Thanks lclaro, I got it... hope this patch will work. Thanks again,
  14. Runis

    Silent Intrusion in BC9

    Hi everyone, I want to make silent intrusion for outgoing calls in a BC9 system. It works fine for incoming calls to ACD groups, as parnum 149 is 0. But, how can I make it work for outgoing calls?? Is there any way in BC9?? Any patch?? Hope you can help me... Thank you all,
  15. Runis

    2B+D ROUTE WITH CISCO 1751 ROUTER

    Hi Astonces, I want to make a Q-SIG between two MD (with 2 router), but the problem is that the connection between the MD and the router is E&M in one side and 2B+D on the other one... Thanks,
  16. Runis

    2B+D ROUTE WITH CISCO 1751 ROUTER

    Hi everyone, I have an MD110 BC10 system and I want to configure a 2B+D route between my system and a Cisco 1751 Router (ISDN-BRI). I have tried all kinds of ROCAI/RODAI variations, the channels are not blocked but it does not work. Please, do you know what kind of route configuration do I...
  17. Runis

    Remote LIM over IP in BC12

    Hi, I need some information about how to use MSED HL950 equipment in BC12: what capacity do I need?? How many channels?? Bandwith over IP network?? Some example, scenario... about an already working system?? Thanks for your help!!!!!!!!!!!!!!