  1. NoypiToits

    not getting the ring back tone some times

    Some times calls are going through and some times giving blank and busy tone(Cause 127: Internetworking Unspecified) error." This issue will not solve by the previous email. Consult to Nortel Distributor in your area to update latest patches for your Nortel 61C. NoypiToits
  2. NoypiToits

    not getting the ring back tone some times

    RGBK XTON 132 If you change the ATRN- COde and the SYSP- INTN, requires INI.. NoypiToits
  3. NoypiToits

    not getting the ring back tone some times

    In your CDB, FTR_DATA and RDB are using TTBL 1 (Tone table) LD 56 REQ prt Type FTC TBL 1 User LD 22 REQ PRT TYPE ATRN (codec) CODE 00 (MULaw) CODE 02 (ALaw) LD 97 REQ PRT TYPE SYSP INTN NO (MULaw) YES (ALaw) NoypiToits
  4. NoypiToits

    Replacing OPX lines

    If the CS1000 is in Alaw DTMF=138, IF MULaw DTMF=014 LD 22 REQ PRT TYPE ATRN CODE 00 = MULaw (CODEC) CODE 02 = ALaw LD 97 REQ PRT TYPE SYSP INTN NO (MULaw) INTN YES (ALaw) NoypiToits
  5. NoypiToits

    not getting the ring back tone some times

    Please check LD 21 Prt type FTR TTBL 0 (Tone Table) Prt Type RDB Cust 0 Rout XX (IAO trunk) DRNG yes NDRI 1 LD 56 prt type FTC Tabl 0 RGBK (Ring Back Tone) xton ? xcad ? NoypiToits
  6. NoypiToits

    Replacing OPX lines

    Hi UnklBuddy, can you please prt in LD 97= XCTP (should be DTMF=138) NoypiToits
  7. NoypiToits

    Nortel Meridian Option 11 new PRI card issues

    Change your Loop timer Config. Framing... LD 73 TYPE PRI2 FEAT LPTI LOOP 7 MFF = AFF ACRC = NO Reset the Pri card LD 96 Dis dch XX LD 60 disl 7 (PRI loop #) ENLL 7.... NoypiToits
  8. NoypiToits

    Nortel Meridian Option 11 new PRI card issues

    Hi nmcmo, please check Cisco side configuration of PRI- LPTI. CRC = NO or YES, if CRC is NO, Nortel CS100 should be "ACRC=no & MFF=AFF" if CRC is YES, Nortel CS1000 "ACRC=yes & MFF=CRC." NoypiToits
  9. NoypiToits

    Opt 51, breakers tripping

    Before you replace the System Monitor, isolate the problem by Unseating the system monitor and the Ringing Generator. Reset all the power switched. See if the system power comes up, re-seat the ringing gen., observed if the green light is on from the Ringing Gen.(your RG is ok). Re-seat the...
  10. NoypiToits

    unable to login after password change

    You changed Admin1 password, but you did not change Password2...Try your old Admin2 Password...default "0000" Villareal
  11. NoypiToits

    cannot add a MC32S card to a CS1000 R5.5 with SSC processor

    Please update & check the MC32 loadware same in CS1000. Villareal
  12. NoypiToits

    Nortel 61C EPABX Upgradation

    Before you Upgrade your 61C, Perform preventive maintenance, Check -48VDC (max. of -52VDC)output from your rectifier. Check the cable of the anlg. extension that always out-of-service. etc.. Villareal
  13. NoypiToits

    Use DID or TIE for new PRI, unable to dial out

    Are the extension in TGAR = 1? If so, chg RDB "TARG = x1" Villareal
  14. NoypiToits

    OPT 11 to asterisk & name display

    LD 16- RDB NCNA yes NCRD yes SCH 0531 Unable to match input with stored mnemonics. Reconfigure accordingly. Villareal
  15. NoypiToits

    OPT 11 to asterisk & name display

    -Disable the Dchannel -Delete all entry in Rcap -ND2 first and then enter the rest. Villareal
  16. NoypiToits

    PCA simultanious ring not working ... pls help

    I use PCA, release 7.5 and no problem at all. TN 100 0 13 05 VIRTUAL TYPE PCA CDEN 8D CTYP XDLC CUST 0 NUID NHTN MRT ERL 0 ECL 0 FDN TGAR 2 LDN NO NCOS 3 SGRP 0 RNPG 0 SCI 0 SSU 0001 XLST 2 SCPW 6339 SFLT NO CAC_MFC 0 CLS TLD FBD WTA LPR MTD FND HTD TDD HFD CRPD MWD LMPN RMMD AAD...
  17. NoypiToits

    PRI QSig between Nortel and Cisco

    Are you installing 2MB (E1) or T1 PRI card? And also check CRC protocol for both Cisco & CS1K. Villareal
  18. NoypiToits

    NCOS set 0 but still can't make external calls on CS 1000

    Check from your Opera if check-in/check-out are synchronize with HMS, and CS1000. Villareal