edit: I tried MAN INT button (btw it resetted the m2250 sets) and no progress on unrecognized chars :/
I did it remotely, so I was not able to test TTY-0.
BEFORE
AFTER
oh, pbx angel shows up again :)
Yes we do have SSC card, and dip switch is on 19.200 (I changed it from 9.600 but as far...
I have a site, running option 11c where I couldnt interract it with TTY-0. Both TTY-0 and TTY-1 is unavailable. I can only use TTY-2 for programming purposes, which was defined as printing "all recieving calls". I tried to change the octopus cable, but result was same. How to fix this and enable...
I achieved this by;
Since 9 is for “select CO in first CO group”
I put gsm’s to group 2
Land line to group 1
Other pbx line to group 3
14 for special code for group 3.
And digit conversation table(270) as
905–> 890205
Everyone can make call to group 3
And most of ‘em are restricted to make...
I have 4 CO lines, 1 one of them is an extention of an another PBX.
So, when users want to call a number,
I dont want to make it select 4th line, only 1st, 2nd and 3rd lines.
And I did a Digit conversation for selecting 4th line as;
when an extention presses 9 --> outside call.
when pressing...
As per output tells,
I do perfectly understand what that means.
It is working fine as locally as I already posted here.
The reason that I am calling IVR is that, there is no need to any human interaction for “answering the call”.
I understand that every information is sent to initiate the...
First of all, remote site is functioning great locally.
Second, my main duty is developing softwares but after the nortel guy retired, I jumped into pbx systems. So, I am a total newbie in both in pbx and pbx networking. I try to figure it out from old avaya documentations. So go easy on me :)...
I have 5 remote sites.
All connected to central site.
If 1. Remote will call 2. Remote site, it sends call information to central router at central site. It routes it to the destination.
And also in every remote site configuration is same. Loop 2, rout 15.
C lover, devoted to JS, writing...
--Single PRI with its own DCH
Here is the TRAD results. First is a Healty Remote Site. Second is the broken one. They seem to be exact!
1. Healty Remote Site
ACTIVE TN 002 01
ORIG 002 01 TIE RMBR 15 1
TERM 010 0 00 12 MARP 0 4991 L500
DIAL DN 4991
MAIN_PM ESTD
TALKSLOT ORIG 27...
Hi,
Briefly,
I have several remote sites, and I am sitting in central site.
They call any-other remote site via center router in central site.
So the path is, Remote Site----> Local Router ----> Central Router ---> Other Remote Site
One of them (Option11c) makes a trouble at sending and...
That's great! Maybe I should do it so.
The only concerning point about this, is,
the international ROUT requires FRL 4, and only attendants has that.
Any other extention cannot dial directly from international ROUT. So, the system will wait until 5th number input then checks for FRL
or when...
I was too desperate :)
I found it HERE.
In case, somebody still trying to find the solution it is ARRN.
When defining an SPN, you could add alternate RLI's for tailing numbers.
in my case, it is sth like this:
REQ PRT
CUST 0
FEAT NET
TRAN AC2
TYPE SPN
SPN 0539
SPN 0539
FLEN 11...
Hi, I have an issue with my local GSM operator.
They define a new prefix, and it clashes with a Turkey GSM prefix:
Local GSM Prefix is 0539 1xx xx xx
Turkey Prefix is 0539 8xx xx xx.
Since in North Cyprus, we use the same Country Code(0090), it clashes with Turkey's GSM Prefix.
(PBX assumes...
>LD 143
CCBR000
.XVR
R>CCOK. (This is current back-up file - about 120KB)
CCBR000
.XVR
R>CCBKP002 Backup image differs from internal backup.**** (this is old backup file - about 1MB)
>
So, it tells it is OK. Should I trust? It is nearly 0.1 x in size...
C lover, devoted to JS, writing...
I have successfully replaced old SSC with new one, and here is the new back-up files:
>LD 43
EDD000
.DAT
DATABASE ISSUE DATE(d/m/y)/TIME SIZE(recs) SEQNO
Main 400T 10/05/2019 at 10:20:04 72 1146
Secondary 400T 10/05/2019 at 01:00:32 72 1145
IntBackup 400T...
The problem was, the second cable, I only soldered the red ones. Now, with all soldered it works. I have connected to SDI Port-0 and loaded a former back-up file to the new CPU. Since it is out-dated, I begin to write current configurations on it. It nearly ends. OH god, I am so happy right now...
Cannot access to pdt. One expert come to help, but even he says, “40 years of exprience, but I never saw sth like this. It is a miracle that it is still working”, oh and also, licence was missing that day too. So he can’t build a new one. (Actually he defines everything on a new ssc but unable...
Here is my drives. They are literally don't answer on any request.
>LD 43
EDD000
.DAT
DATABASE ISSUE DATE(d/m/y)/TIME SIZE(recs) SEQNO
Main database not accessible.
Secondary database not accessible.
IntBackup 400T 14/02/2014 at 01:00:34 70 1126
PCMCIA database not...
One of my Option11 is currently dying. (His doughterboard is dead).
No Back-up, no PCD or anything else.
So, I started to build up a new CPU according to it.
But the issue is, neither I nor the local market have an octopus cable (In North Cyprus).
So, as instructed here, I have tried to make a...
[Question]
Is there a way to list busy extentions?
[Description]
The problem we having is, there is a cabling problem, and time to time,
some of my extentions are hanging in space. And they are making my operators crazy.
This (answer of my question) will be a relief, because you know, in the...
The thing is, my organization will keep these systems for a while. [Funds and stuff].
My approximation is at least 3 years nortel's are with me.
I have to do the administration and maintanence of these systems
in following years. Thus and so...
C lover, devoted to JS, writing c#...
Nortel...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.