fcpli , thank you for the note , and sorry for the misunderstanding .
there was old Ericsson tool called Signal Interpreter for SLP60 Signal trace , and now its built in and exist in the MTS.
hi ,
to check the status for the trunks use the following command
susip:rou=x,tru=all;
this command before TSE6.3
new command
resource_status --externals --route-number x --trunk-number 1-1..1-x --traffic-status
to initiate DID
number_conversion_initiate -entry xxxx -conversiontype 0...
Dear all,
i have An Ianttend system connected to TSE6.3 (SIP-TRK) and the Mxone TSE6.3 is connected to another CUCM 10.5 system through
Qsig Link and SIP Trunk
Inattend <<------SIP TRK--->> Mxone TSE6.3 <<------SIP Trunk-->> Cisco CUCM 10.5
, when directing the calls from the Mxone to CUCM...
dear all;
i have a mxone 6.0 system , i need to stop all of types of recalled calls to the
DBC4224 operator console.
thank you for your help in advance
Dear all;
i have a problem with our Mxone 6.0 system , i have two analog trunks , if i make two outgoing calls by a digital or operator extension
if i join the two trunks on conference or make a transfer , the two called parities hear a big noise like the sound of modems , and they have a very...
thank you for your help
i know how to change the Timer datablock, but my question about the value i have to change to it
do i have to raise the time elapsed before the attendant to recall on no answer calls?.
if set this to zero no unanswered calls will be recalled to the attendant?
Dear Gene,
thank you so much for your help.
i found this thread regarding the same case i posted could you please clarify the solution more .
http://www.tek-tips.com/viewthread.cfm?qid=1662589
thanks alot sir
dear all
i have the following problem , all the External incoming calls answered by voicemail system and then blind transfered to the
attandent console (M2250). when the attendant console reply the call and transfer it to the internal extension , if the call is not
answered by that extension...
this the CDR prameters of my system
>ld 21
PT1000
REQ: prt
TYPE: cdr
TYPE CDR_DATA
CUST 0
TYPE CDR_DATA
CUST 00
CDR YES
IMPH NO
OMPH NO
AXID NO
TRCR YES
CDPR YES
ECDR NO
BDI YES
OTCR YES
PORT 6
CNI DGTS
BCAP NO
CHLN 0
FCAF NO
and the CDR parameters of the Pri...
see this is an internal call No problem
L 107 00 5539 5962 024.1.04.09 020.0.07.01 04/01 11:13 00:00:58 0000 0000
this is incoming call from cell phone 775799299 through the Pri route 101 , 5980 is the group hunt for the auto attendant system
N 023 00 T101 017 5980...
dear sir
the CDR format is already OLD Format
the problem i have is in Incoming call to my PBX ,
if one from outside call the incoming PRI route of the PBX
the format of the CDR comes in two lines , the second line contains the outside calling party.
see this
Dear All.
we have a Nortel Cs1000M Rls4.5 system , we bought a new billing system from local provider.
we have a problem with the incoming call records , the new billing system can not handle it because
it comes in TWO STRINGs , the billing system only receives One sting for each record.
can we...
our system is cs1000 upgraded from option 81 . the clock controllers are connected to the refernce PRI.
do you advice me to switch off the clock controller of the second shelf for a minute and then siwtch it on once again?
dear sir
thanks alot for your help
first i changed the framing to CRC
the reference clock is in loop 34
REQ prt
TYPE syti
SCH0111
TYPE pri2
FEAT syti
PREF CK0 34
SREF CK0 FREE RUN
PREF CK1 34
SREF CK1 FREE RUN
CCGD 15
CCAR 15
EFCS YES
how to set this reference clock to...
first thanks for reply
here the output when the link is down
PRI2 LOOP 54 - ENBL
REF CLK: DSBL
SERVICE RESTORE: NO
ALARM STATUS: OOS NO AUTO STRT
CH 01 - IDLE DID VOD * CH 02 - DSBL DID VOD *
CH 03 - DSBL DID VOD * CH 04 - DSBL DID VOD *
CH 05...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.