not a pri just a t1 with dids coming over it, this phone is normally forward at night and during the weekend, just want to do the same thing, thought i could with an sdn
I have built a new app and sdn of 7200 and used ncfw of 7000 in load 23 when build 7200, i can dial the app and use it but when i try to forward my main set to it, which is a 3904, i get a busy signal, any ideas?
I have a 201i that is used for mailboxes only at the moment, I need to build an application for auto attendant ,we are going to forward the main phone to the sdn I build for this app. My question is do I need to build a new acq queue for this app or can I use the one that my mailboxes use?
I have had 2 callpilot 150s lose there memory.
I reprogrammed one and it lasted about a year until
this weekend when they took a sustained power outage, the
other is just about 2 years old and never had any problems with until this long power outage, they are reprogramming fine, but will they...
yes i can dial fine. when the handset is on hook and i press the call forward key the display says release and try again, if the handset is off hook and i press the call forward key and put the number in it calls the number like normal without even noticeing that i pressed the call forward key.
i am needing to forward this extension at night to a answering service, i thought i had it, but i was wrong.
when you press the call forward button it say release and try again. any suggestions?
REQ: prt
TYPE: 3902
TN 10 11
DATE
PAGE
DES
DES 3
TN 010 0 00 11
TYPE 3902...
the short cable from the smart jack to the m1 cable is home made, and it is a tmdi, we own the circuit as well and the other day we ran to a loop 4 or 5 minutes, clean and when we turned it back to the 11 it started taking slips. my cc was red so i disabled and reenable it and the tmdi card it...
here is my ssck
this is my on t1
the card goes straight into the smart jack.
no adtran or anything.
what is layer 1
.ssck 0
ENBL
CLOCK ACTIVE
CLOCK CONTROLLER - LOCKED TO SLOT 2
PREF - 2
SREF - FREE RUN
AUTO SWREF CLK - ENBL
NO ERROR
IP DB PORT 1 DSBL
IP DB PORT 2 DSBL
IP...
i am having a lot of dtc dta dti anybody know how to fix this here is a log and lcnt
TTY #01 LOGGED IN ADMIN1 08:01 20/7/2007
>ld 60
DTI000
.lcnt
DTI TRK LOOP 2
TRSH CNT:
BPV -010
SLIPD -000
SLIPR -000
LOSFA -002
OS_BPV -000
OS_LOSFA-001
OS_YEL -000
.prt
DTI002...
Has anyone ever had there M1 disable ports for no reason.