Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations dencom on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by pcrequest

  1. pcrequest

    check # of current calls?

    Here's what I suspect is the NVRAM pack: NNTM845662KU NTBB08GA-93 Rel 02 2002/10/03 MICS NVRAM CART MADE IN CANADA 0009
  2. pcrequest

    check # of current calls?

    Is 7.1 a MICS version? How would I upgrade this? BTW, there was no alarm code this time around. Our carrier said they didn't (can't) reconfigure anything regarding the B Channel Service Messaging discussion. I'll see what our Nortel vendor thinks.
  3. pcrequest

    check # of current calls?

    This problem seems to be back. Some users were unable to make outbound calls. I could only get up to 2 in + 2 out, or 4 in and 1 outbound before we "ran out" of lines. Called in a trouble ticket, and referenced our old ticket. Provider said CO switch was ready to take more calls, even though I...
  4. pcrequest

    check # of current calls?

    PERRYPJ, our carrier thought that would be a good idea, and they said they don't get a lot of requests to do this.
  5. pcrequest

    check # of current calls?

    I ended up power cycling. I can use all channels now. Causes for the Alarm 75? It seems we must do this every 3 months since we got our new carrier.
  6. pcrequest

    check # of current calls?

    Yes, full PRI, so 23. I can't make the 3rd outbound call though. Carrier called back and said everything looked good on their end. He could see two calls connected, but when we try a third, carrier doesn't see a request to grab an open channel. I just get silence on the earpiece. They...
  7. pcrequest

    check # of current calls?

    How might I check the number of active external calls? I noticed an Alarm 75 this morning. We can only make perhaps 2 or 3 external calls on our plain old PRI. Googling, I see this is some kind of PRI clocking issue, and I've contacted our phone carrier. We have a Norstar KSU/PRI MICS 5...
  8. pcrequest

    how many digits passed

    We have a Norstar KSU/PRI MICS 5. Handsets are M7310. 61 DIDs. We are switching carriers. I do as much maintenance as I can, and use a local Nortel hardware vendor for important things (like when we switch carriers). They are scheduled to assist in cutover in several weeks. My phone hardware...
  9. pcrequest

    Weird Comcast routing

    I noticed that our latency from our Minneapolis office (which has 50/10 Comcast Business class) to a server in our Chicago office (a different ISP), is either routed a fast way through Chicago, or a slower route through Denver->Dallas->Chicago depending on which public, static IP address we...
  10. pcrequest

    low volt gang boxes

    Thanks, all. I started out with metal boxes, but they just didn't seem right. I found what I wanted are also called backboxes. My local store carried these and they should work fine...
  11. pcrequest

    directory feature?

    I suppose I could just dial our main number, then use the auto attendent feature to dial by name. A bit ham-handed, but easier than remembering feature codes.
  12. pcrequest

    directory feature?

    Yeah, that code I mentioned is probably in the vmail box. There is a delay when i punch it in, like other 9xx codes. It seems like an obvious feature in the KSU to have (easily) implemented. All the DNs are named. I map to a person's name. Would be nice for anyone to refer to a list of DNs...
  13. pcrequest

    directory feature?

    I administer a Norstar KSU/PRI MICS 5. Handsets are M7310. Is there a way to look up anyone's extension and call them? We always print off a list of names and extensions, but that's not always convenient (gets lost). I see at this post http://www.tek-tips.com/viewthread.cfm?qid=726076...
  14. pcrequest

    low volt gang boxes

    yes, i need to mount to the faceplate to something. i see on a metal box, the punchouts seem sharp, that's one consideration.
  15. pcrequest

    low volt gang boxes

    I haven't done much of this before, so bear with me. I need to terminate some low voltage wires (HDMI, CAT5e) inside a cabinet. I've got the faceplate figured out (Hubbell iStation). I plan on surface mounting a single gang box to the interior. Should I use plastic, or a metal one that...