Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations dencom on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by FordMan77

  1. FordMan77

    Upgrading from Legend 3.1 to Magix 4.0

    I knew there was something I was forgetting, lol... The ATL boards. I'm going to have to contact the customer and find out. I know they were in the process of switching over to all MLX sets, but there still may be some BIS phones out there.
  2. FordMan77

    Upgrading from Legend 3.1 to Magix 4.0

    Thanks TTT. That's what I was planning to do if it would indeed convert. I'd rather have it fail in the lab then onsite in front of the customer. And merlinman, it looks like I lucked out and got one of the factory CKE4 processors. See sys setup below... Slot # 0: CKE4 CPU A Slot #...
  3. FordMan77

    Upgrading from Legend 3.1 to Magix 4.0

    Other than replacing the processor w/ the Magix style, is it possible to convert the existing Legend R3.1 translations to Magix R4.0? Never attempted this big of a release jump and not sure it will convert correctly.
  4. FordMan77

    S8700 server fan issue

    Working on an S8700 server (duplicated) running CM 2.2.0. All was well until the server room A/C died over the weekend and everything overheated. I cleared the alarms for the high temp and both servers are running alarm free. Problem is when I click on Temp/Voltage from the webbrowser, one of...
  5. FordMan77

    Merlin Messaging Not Disconnecting

    Thank you all! I will push back to Telco to make them fix this.
  6. FordMan77

    Merlin Messaging Not Disconnecting

    Update- I changed the dial 0/timeout action to disconnect and tested. When I call and press 0 is disconnects my call and I am able to call it right back, so when the Messaging is set to disconnect it works, but when not programmed to do so, it hangs the line.
  7. FordMan77

    Merlin Messaging Not Disconnecting

    Alright, I've changed both groups to Linear ring, and changed the dial 0/timeout action to leave a message in the gen. mb. This all works correctly. I set my reliable disconnect to ON again for these trunks, and changed the Hold timer back to long as it usually is. Now when I call, I get the...
  8. FordMan77

    Merlin Messaging Not Disconnecting

    I noticed that when I tried to login to the VM and did not have the correct password enough times that when the Messaging hung up on me the line actually disconnected, as I called back on that same line. I guessed the password the 2nd time around and got in. After some digging, I found that...
  9. FordMan77

    Merlin Messaging Not Disconnecting

    Ok merlinman, I changed the Hold Disconnect to short. No change there. I also changed the Reliable Disconnect to NO for these lines. Still nothing. What other things might you have in mind to test?
  10. FordMan77

    Merlin Messaging Not Disconnecting

    Did not test it personally, as it is 2 states away. Having to take Telco's word for it.
  11. FordMan77

    Merlin Messaging Not Disconnecting

    Having an issue w/ a Merlin Messaging not disconnecting calls on 3 copper trunks. I have them set to LS-Disconnect YES in the switch, and the ports are rotary enabled (which shouldn't matter for this). Verizon has disconnect set on their lines. If they test at the Demarc, the calls disconnect...
  12. FordMan77

    Answering Machine beep causes Fax to start

    If this users home is called from a cell phone, I'm told it does not occur. The only thing that I can think of is that a fax machine/modem somewhere in the building is half-tapped onto the same wiring as that analog extension, and when it hears the beep it begins to attempt to talk to it as it...
  13. FordMan77

    Answering Machine beep causes Fax to start

    CM 5.1.2.416.4 on S8730 Duplicated Servers w/ G650's and 2 PN's Have a weird issue that I've never seen before and hoping someone can shed some light on. User at analog ext. calls outbound to her house (local call) and gets their answering machine. Leaves a message as normal. This machine...
  14. FordMan77

    Group Calling Workaround- Will this work??

    Trying to help a customer work around some coverage issues and want to see if this idea will work or not. The idea is to have calls to a particular group ring to another ext., problem is that ext. is already part of another calling group and we all know you cannot be a member of 2 calling...
  15. FordMan77

    Definity Audix card type mismatch?

    Ok, so that explains that, thanks! You state the TN566 would have 3.1 software, even though when logged into the Audix, its a 3.2. Is this just another "the way the switch sees it" deal?