You will need to program a COT route in ld 16 and then program a COT trunk in ld 14. Once this is completed you then cross connect the second pair of the trunk TN to the relay. Each trunk TN is two pair and the second pair of each trunk TN is a contact closer. Then program an Hot D key with...
We are way past that. We have looked at all the logs we can. Its in Avaya design now. I'm looking for others that might be having the same issue and once there is a fix I will post the solution.
Don6531
All, I have a good one here. I have 1 CS1000E 7.0 & 3 CS1000E 7.5 systems running all 3904 and resaving phantom ring on them. The phantom ring is random, sometimes 2 or 3 phones will start ringing. The phantom ring locks up, the red light lights all keys flash, no brake in the ringing, no...
I would check LD 86 and print your ESN block to see if TAGR = Yes in this case if the TGAR is 5 on the set and TAGR is 5 on the route the call will be blocked. If TAGR = no in the ESN block then the call should work.
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.