Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Chriss Miller on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by dapster1

  1. dapster1

    Option 11 Universal Trunk Card Pinout

    Use pairs 1 3 5 7 9 11 etc for standard CO trunks
  2. dapster1

    3902 Digital phone random ringing

    I have read this post Change tn ports as a start or replace digial Line card. verify 3902 sets by replacing them I used 3902 sets in a utility setting and they did some strange things Good luck
  3. dapster1

    TTY - PMS connection not working - Nortel CS1000 Rls 7.0

    I have read this post As a try..when you connected your laptop did you change the user type to MTC so you can you can talk to pbx? This will prove the tty port side is good.
  4. dapster1

    Analog line- Provison to another trunk group

    Please review this and make suggestions accordingly. I Have a G430 Media Gateway PBX S8300 / release cm5.2 My customer site has 85 sets all digital, with 1 PRI-T1 for all calls in and out configured as as TRU-1. I also have a TRU-2 for a backup from another carrier that consists of 5 analog...
  5. dapster1

    Avaya g430 to g450 upgrade

    Thanks for all the direction advice on this question. I believe my customer will allow me to hire an Avaya Business Partner to upgrade this site as you have suggested. I will lookup the Provision tool and learn all I can about it. If the migration software is similar to Nortel I would rather...
  6. dapster1

    Avaya g430 to g450 upgrade

    I Have a G430 Media Gateway PBX S8300 / release cm5.2. This system is all digital (no-iP) and this acct. needs additional digital ports and analog ports. I already have 2 em200 modules installed on this g430. I would like to upgrade this customer to the g450 cabinet to give me more slots. So...
  7. dapster1

    Can a 2 way HOTLINE on multiple 3904s have selective ringing?

    Here is my scenario, I have 16 3904 stations with the same 2 way hotline to another branch office. I use the key 5 hot d 5 XXXXX XXXXX and it works great. The same hotline key is programmed identical on all 16 sets. Here is my question????? Is there a way I can set only 9 phones to ring...
  8. dapster1

    M3904 DN not doing to voicemail

    Suggestion....... You can add the ext in question as a secondary DN in the voicemail profile of all the sets. Also, you may try building a 500 set as the same ext and using marp to go to voice mail. Analogs take presedence in this config.
  9. dapster1

    cs1000e iapg question

    We have the same setup in our Call Center IAPG 1 AST 00 03 THIS MEANS: Meridian Link Unsolicited Status Message (USM) group IAPG- assigns AST DNs to a status message group defined in LD 15. These groups determine which status messages are sent for an AST set. The default Group 0 sends no...
  10. dapster1

    CS 7.6 Problem : PRI247

    Check the PNI of your routes....should be a 1 on both sides. Also verify rls settings on dch configurations Hope this helps
  11. dapster1

    Line Issue

    Check you spans. LCNT and verify slips, bpvs etc, Check your clock tracking on Primary
  12. dapster1

    PRI-T1 clocking slips

    Yes ....I think I do have one of these in my truck or I can make one very easily Thanks Tier3 and I will post back in a few days with my results when I can get back to that customer.
  13. dapster1

    PRI-T1 clocking slips

    Yes I do have a console cable (crossover correct)...? Do i need to do this on site because I have been remoted in via dialup
  14. dapster1

    PRI-T1 clocking slips

    Well, I just have found out that I do not have the Gateway 430 password. I only have the CM and the Server passwords.So I did a little searching around and called a tech and he has told me to use root root but that does not work, I have also seen (init password???) ,root root1, and root...
  15. dapster1

    PRI-T1 clocking slips

    Thanks alot...I will try this later this afternoon. My customer says alot has cleared up since i changed to error correction to Yes on the ds1 config, but there still are some crackling/slips on the span. Carrier (as Usual) says he is running clean isolated from the Avaya pbx on a test last...