I have read this post
Change tn ports as a start or replace digial
Line card. verify 3902 sets by replacing them
I used 3902 sets in a utility setting and they did some strange things
Good luck
I have read this post
As a try..when you connected your laptop did you change the user type to MTC so you can you can talk to pbx?
This will prove the tty port side is good.
Please review this and make suggestions accordingly.
I Have a G430 Media Gateway PBX S8300 / release cm5.2
My customer site has 85 sets all digital, with 1 PRI-T1 for all calls in and out configured as as TRU-1. I also have a TRU-2 for a backup from another carrier that consists of 5 analog...
Thanks for all the direction advice on this question. I believe my customer will allow me to hire an Avaya Business Partner to upgrade this site as you have suggested.
I will lookup the Provision tool and learn all I can about it.
If the migration software is similar to Nortel I would rather...
I Have a G430 Media Gateway PBX S8300 / release cm5.2. This system is all digital (no-iP) and this acct. needs additional digital ports and analog ports. I already have 2 em200 modules installed on this g430. I would like to upgrade this customer to the g450 cabinet to give me more slots. So...
Here is my scenario,
I have 16 3904 stations with the same 2 way hotline to another branch office. I use the key 5 hot d 5 XXXXX XXXXX and it works great.
The same hotline key is programmed identical on all 16 sets.
Here is my question?????
Is there a way I can set only 9 phones to ring...
Suggestion.......
You can add the ext in question as a secondary DN in the voicemail profile of all the sets. Also, you may try building a 500 set as the same ext and using marp to go to voice mail. Analogs take presedence in this config.
We have the same setup in our Call Center
IAPG 1
AST 00 03
THIS MEANS:
Meridian Link Unsolicited Status Message (USM)
group
IAPG- assigns AST DNs to a status message group
defined in LD 15. These groups determine which
status messages are sent for an AST set. The
default Group 0 sends no...
Yes ....I think I do have one of these in my truck or I can make one very easily
Thanks Tier3 and I will post back in a few days with my results when I can get back to that customer.
Well,
I just have found out that I do not have the Gateway 430 password. I only have the CM and the Server passwords.So I did a little searching around and called a tech and he has told me to use root root but that does not work,
I have also seen (init password???) ,root root1, and root...
Thanks alot...I will try this later this afternoon. My customer says alot has cleared up since i changed to error correction to Yes on the ds1 config, but there still are some crackling/slips on the span.
Carrier (as Usual) says he is running clean isolated from the Avaya pbx on a test last...
I would appreciate some help on this in Tampa on an Avaya 430 cm5.2
My PRI- T-1 slips on the list measurement status all day long. There is only 1 span for all calls in and out. I am familiar to the change sync commands but my system does not recognize these commands. I have set my DS-1 to...
You know you are a Nortel Tech when......
In an Avaya class your training partner doesn"t know what CLI is and how fast you can type through the Loads!
The system is using the caller id of the originating call. There are several things that can be tried here....
In Mermail........ add 7855 as an Ext Id for 4014 box attributes. (if it is not a dn conflict)
This has worked in several apps for my company.
I have used both PuTTY and Secure CRT for several yrs. I do like PuTTY better because of its ease of use and its IP SSH applications or base serial connections thru modem or direct connect.
Jason
See if you can make the 2616 work at the PBX room TN closest to the switch tail. If it works closest to the switch and not at the jack, it may be a loop lenghth problem or funky impedance issue with that set.
With that being said....you could try amnother TN off another Superloop IPE shelf...