Good Morning,
Does anyone know of a IP-CCIS SV8500 to a SV8100 cheat sheet that shows the 8500 programming side? We recently moved from a Nortel 61C to a NEC SV8500 and installed IP-CCIS to one of our SV8100’s. Coming from Nortel I’m still dealing with a huge learning curve. The installers...
Hello all,
We have a 2400 that’s currently being upgraded to a SV8500 W/UM8700 voice mail. All of our phones are Dterm Series i 16 button phones.
Question: Is there a way to program the “Message” button on these phones to work with our new UM8700 voice mail?
Also
Question: Is there a...
Thank You, Thank You!!! It was the "Minimum Digits" on the MDR2000 that was set to 4, I changed it to 0 and we now see Internal calls.
THANK YOU trvlr1, SL1M1, GHTROUT, jaxuser for all your time and efforts... and especially your patience!!
This is probably where the problem exists. This is the "Collection Script" file
(mdr2000.col) thats used by OTM to pull CDR from our MDR2000. Is there anything
here that could be causing the trouble?
;*******************************************************************************
; Script...
Ok doing the following in the MDR2000 I can see the "L" records with ext to ext (Internal) calls listed so I know it's getting to our OTM... or at least that the MDR2000 is seeing it.
M2K> Mode --> MDR BCD
M2K> Open Link (Enter)
L 088 00 DN5129 DN4770 03/01 11:40:11 00:00:10.0...
I tried toggling FCDR to NEW, then OLD, then NEW again with no luck. I also tried your suggestion of adding CDMA to two extensions and making calls to each other with no luck. Thanks for the suggestions though GHTROUT!
Well I've narrowed it down to one of three things: It's not leaving the...
Other than ICDA being set in cls for all phones is there any other settings on the switch side that would prevent internal CDR from being sent to the MDR-2000?
Thanks GHTROUT,
I kind of thought that same thing after reading more posts here. Unfortunately the Costing in OTM's Telecom Billing System is only seeing Ext(D) to Trunk(T) and Trunk(T) to Ext(D) no Internal(L) calls.
Is it possible the MDR2000 collecting script "mdr2000.col" is filtering out...
Yes I tried setting Internal calls to a "Test" costing sheet with all zero amounts with no luck. It seems like I'm missing a setting on our 61C because during the Collecting process in the Data tab I never see any “D to D” calls only “T to D” and “D to T” calls.
I am trying to get our 61C, MDR2000, OTM to report internal calls. Sorry guys I’ve looked at every post here on internal call reporting with no luck. Here’s what I have:
• Every phone has ICDA, CNDA in cls
• I have “Internal Calls (Ext->Ext): Yes” set on MDR2000
• OTM external call reporting...
Ok I was able to add the new LD area code "567" and it works perfect however, I'm still confused with the way "fcas" works.
We basically have two area codes that are both local and local toll, 330 and now 234. In fci 1 for area code 330 (Main) they allow all local prefixes. In fci 2 area for...