Hi,
Currently there are 83 IP phones and 6 Voice mail ports. The remaining 3 Signaling are being used by something else (I don't what it is utilizing these ports).
Dear All,
There is a BCM400 Rls 3.7 installation that I have done. Now there are 82 IP phones connect with fax unified messaging and voice mail. As per my understanding BCM400 is scalable 90 IP users but in this current scenario when I'm trying to connect 83rd phone it does not register with...
hi guys
how to know which port in the cisco switch configured to connect on it a turret with speaker module.because i am going to connet a new turret which has a 4 channel speaker module attached to it.
sorry for this question.
thanks.
Dear All,
Now I have change the situation. I'm coonecting the BCM and H323 provider directly point to point.
Situation 1: From my PC I can ping the BCM and the H323 Gateway.
Situation 2: From the BCM I can ping my PC and I get an error.
Situation 3: From the provider side, they can ping my...
Dear All,
I have done the networking between ISP having cisco device and the BCM200 using IP trunking H323 protocol. The BCM running 4.0 software release.
I can make an outgoing call, but the second party can not hear me (I can hear him very well).
In case of the incoming call, the caller can...
Hi,
MitelTech, sorry that I did not mention the message type. It is a Callback message. Also this extension is not in a hunt group.
For the second option about the multicall key appearances, I have to check it.
Alaa
Hi,
MitelTech, I already did the steps you mentioned, but still the phone lamp flashing. I want to mention something strange happening which is that the phone light will keep on flashing if the users did not listen to the message in the same day they received it. And they listen to the message...
Hi,
I have 3300ICP Mx controller with 7.1 software installed. Everything is fine except that when they received a message, and after erasing the message the light on the phone will remain flashing indicatiing that there is a message. But actually there is no message at all?
What will be the...
Hi,
Then in this case I have to create the destination codes from 60A to 69A, similarly from 10A to 19A, Which I think it is impractical.
Also I have tried to rename the 6 and 1 to any another range but there is no way in doing it.
Hi,
I need to do a VoIP networking between a BCM400 Rls 3.7 with a AVAYA system using H323 trunks.
Site A: The extension range 3xx, 6xx, and 1xx having the AVAYA system.
Site B: The extension range 7xx with a BCM installed.
The VoIP networking is totally operational using the access code. But...
Hi,
I'm using the boot line command. Also Im sure that the HD is OK, because it is a new one. As far as I know that one of the Mitel channel have tried it, and it is working fine.