Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. landei

    Problem with Grid and Windows-XP

    Hey webrabbit, my english is not the very best. Yes it is a COBOL question. I hope, you will understand what I mean.
  2. landei

    Problem with Grid and Windows-XP

    When i added a new line in a grid under Windows-XP, i can see the new added line. The activated cell show a frame. Then i can type any digits. That is ok and normal. But when the grid contians many lines, so that the scrollbar on the right of the grid is visible, the contents of the grid will...
  3. landei

    Cobol and Internet-Explorer

    Hi Glenn, many thanks for the helpfull massage. It also works !!! Greatings Helmut
  4. landei

    Cobol and Internet-Explorer

    Hi Clive, many thanks for the helpfull massage. It works !!! Greatings Helmut
  5. landei

    Analysers for COBOL

    Hi Captain Awesome, few days ago, i have a telefon-call from a company. They have a Cobol-Editor. He produce a structogramm. I dont need such things and so I have not the name of the company. The location of th company is germany, the city is "Nürnberg". I know, it is not very helpfull...
  6. landei

    Cobol and Internet-Explorer

    O sorry, there is a mistake!!! Both version (my version an the version of my customer) of Explorer ist IE 6 not IE 5. @ clive the length of the first filler ist 50 Bytes not 49 Bytes. It looks a little bit shorter, but it isnt. Yes there is a varible in the parameter (the UPS-package-number)...
  7. landei

    Asleep at the Wheel

    There are 2 solution in ACUCOBOL: 1. call "C$SLEPP" using 100 2. accept field before time 100 The time is allways 1/100 second.
  8. landei

    Cobol and Internet-Explorer

    In one of my programs is a call for the internet-explorer 5.0. The call includes the interface for the internet-page to call. It is the page for "UPS-Tracking". I have find out, that the interface of my IE-5.0 is max. 256 characters. This is the content of the call-command: 03...
  9. landei

    Imbedding Postscript to Create CODE 39 Barcode Font

    hi jrmorin, I have a solution for EPSON-Line-Printer or Printer, who works in EPSON-Mode. It is very easy, to print Barcode. The program create a short escape-sequence for send to the printer. You can get the code, if you want. greatings helmut
  10. landei

    error code 231

    Hi, it´s allways the same question??: what compiler you used ??? I know, error code 231 ist not ACUCOBOL !! Regards Helmut
  11. landei

    Rt error when running cobol application

    Hey lonufer, it is very important to know, what cobol-version you use. Im sure, it is not ACUCOBOL!! This error ist unknown. Regards Helmut
  12. landei

    Flat File trailing blanks or spaces

    Hey jmanj, allways the first step, if I put values in a data-set is the command: "initialize name-of-the-data-set" All "PIC X-Fields" contain spaces All "PIC 9-Fields" contain zeros Regards Helmut
  13. landei

    PC COBOL to Command Line

    Hi Clive, my Compiler is ACUCOBOL. The command for the command-line is call "c$system" using parameter The parameter is a field in the working-storage. Example for start the internet-explorer: Working-Storage-Section. 01 system-command-line. 03 my-browser pic x(45) value...
  14. landei

    Cobol an Email

    Hi Clive, it works!!!!! And it looks good as HTML-Page on target site. Thank you for the good idea. Now I will make a little "cosmetic". It was not a problem, to convert to ACUCOBOL. My problem now is the multiuser-working at the same time in a great network with 100 user. You will send the...
  15. landei

    Cobol an Email

    Hi Clive, it is a complete other way for the solution of my problem. I don´t fight with "MAPI", I use the "mailto-Method". It is a greate idea, thank you for help. I will try it. Regards Helmut
  16. landei

    Perform? Call?

    Hi, there is a great difference between call and perform. With call "another-programm" you start a separate programm. The mainprogramm waits, till the end of the called programm. The communication between the programms ar the fields after "using". You use "call", when you need the result of...
  17. landei

    Embedding SQL in Cobol

    Hi Pootytaint, look at http://www.acucorp.com. There is a product with the name "AcuSQL" but I have never use this tool. Regards. Helmut Langguth Germany
  18. landei

    Cobol an Email

    Hi Frederico, the platform is WINDOWS (NT.... 2000....) Regards Helmut Langguth Germany
  19. landei

    Cobol an Email

    Hi, I look for a solution, to send Email with a Cobol-Programm. My Compiler is ACUCOBOL Version 4.2. I know, it is not the newest Version!!! Thank you for help.
  20. landei

    Anyone familar with XANG???

    Hi folks! Anyone here, who worked with XANG (one of the Apache XML projects)? How comlex is it? What are the limits? Should I use it :-? Bye! Landei

Part and Inventory Search

Back
Top