Does anyone have the pin out for the console cable for an M770? Having issues with dead air calls intermitently and believe that the timing source is not set on the M770. Any help would be appreciated.
This is what it looks like right now. I haven't made any changes yet. Looks like it's enabl already..
DTI TRK LOOP 10 - ENBL
FFMT/LCMT/YALMT: D4/ AMI/DG2
SERVICE RESTORE: YES
YEL ALM PROCESS: YES
ALARM STATUS : RED
CH 01 - DSBL CO VOD CH 02 - DSBL CO VOD
CH 03 - DSBL CO...
Yes. I lost my notes. I need to know how the console cable is made. Not sure yet what the following is too
Bits Per Sec
Data bits
Stop Bits
Flow control
I was not able to find the Maintenance section. I was hopping to find out what these error were when I display Error and I see error type. Can you send me to that location.
I do see that I have two T1's out of service. How can I enable them and disable them? I only know of one of them down. I want to enabl one and see what happens and if it's the wrong one, then I can disable it and re0enable the other one
I have 4 T1's coming into my Meidian Option 81. I know that two of them are local and two are my long distance. Can anyone tell me how I can check the staus of the T1's? I have one of them out of service and not sure where to look.
We had a guy call us last month of 900 times but we were able to get his cell number. Please we found out what 800 numnbers he was calling on. We made a change on the VRT table and change the statement in the Vector. Now if he calls it will look at the ani and route to the NY PD.. I bet he stops...
I'm trying to add a VAL Board and just want to make sure that I haven't missed anything. I add it but unable to ping the board when I'm done adding it. I have a S8710 G3R V13.
add ip-interface 15a07
Add Node Name = val05
subnet Mask = 255.255.255.0
Gateway Address = 10.4.4.11
Enable Ethernet...
Do a "change synchronization port-network xx" on the cabinet your having the issue with. You can chose a different T1 to pull your sysnc from. I have both " port-network & ATM" and you can change both to different T1's. I have a S8710 & S8720 Switches.
I have added a new Trunk Grp 5 and the signaling Grp 11. I know that my D channel is on the 4th curcuit. I want to be able to test outside dialing from my ext - 79100. What do I need to change to make this possible to dialout of this trunk grp? Do I need to change the "ARS ANALYSIS"? This is...