I will be on site to test again tomorrow.
Pretty sure I tried what you said and it did not work.
But I will test it again tomorrow.
I will let you know thanks for your help.
Its a g3v8
When I turn queuing off the group rings busy.
ACD Y
Queue Y
Group Type ucd-mia
Queue length 10
Night service dest 251
Redirect rings set to 4
Everything else is default.
I am trying to get a ACD group setup as UCD-MIA to go to vmail box if all agents are busy or do not answer the phone.
I cant seem to get it to follow a coverage path.
No vectoring in switch.
Appreciate your help.
I have a G3i-V11
Installed a 429d diod/co card and with loop start lines and caller ID.
As soon as I enable caller ID on the trunk group the calls no longer ring through to the Attd.
analog caller id is turned on in customer options i have tried all 3 protocols bellcore, ntt, v23-bell.
Anyone...
Installing a new t1 on a g3 we dont have the adaptor and were using an external csu. Does anyone know what pins off the back of the switch that it uses. Pretty sure back in the day i did it and just wired out the first 4 pairs to a jack 568b.
yes but only if there are no agents logged in. not if they are busy. currently i am using qing and if there are no agents logged in it just sits in q forever. i would like it to go straight to vm. but dont necesarily want them to have to force the group out of service.
is there a test condition to see if agents are logged in before it sends it to the group? i am not logging them all the way out either just using the group enable/disable.