It was built out as TMDI. Should i change it to MSDL on the RDB to MSDL.
I wonder what this button does?
JC Walters
2K Communications Inc.
Columbia, SC
Yes i have checked the CDB for isdn. I have rolled cards and clock source. I have dropped the TMDI and renabled with FDL. I can loop the card back to the system and BCh goes green. But when i try to go live i get the DTA001. I am using a DB 15 with 1, 3, 9, &11 and and have verifed with the LEC...
Could anyone please give me a heads up on way im getting a DTA001 (database not found) on new PRI. All LDs have been programmed 14,15,16,17,& 73 but when i go to bring up the loop I keep getting the same error.
TMDI 11
DCH 11
CC 1
All built for PRI/ISDN
Any help would be greatly appericated...
Just checking to see if any one has done upgrade to 7.0 and had any issues.
I wonder what this button does?
JC Walters
2K Communications Inc.
Columbia, SC
Call comes into the main operator on her 2250 If she cant get to the call the customer wants it to roll to the AA for back up coverage. I have tried the FDN to the Callpilot Main CDN and Express messaging CDN but i get RNA.
I wonder what this button does?
JC Walters
2K Communications Inc...
Is there a way or work around to cfw NA/Busy to Callpilot Acd for operator back up?
I wonder what this button does?
JC Walters
2K Communications Inc.
Columbia, SC
Ok i found our difference's your IFC is SL1 and I am using ISIG. The Mitel has to have QSIG(ISIG) so Nortel here i come.
Thanks for all your help in this matter.
I wonder what this button does?
JC Walters
2K Communications Inc.
Columbia, SC
John, is there a way that i could get a copy of the route set up for your columbia to charleston. I cant change the RCAP to nd2 on the d unless i set it up on the route.
SCH 0531.
I have traffic both ways and NDI or NDO does not work. I have tried to rebuild the d for nd2 but still SCH's me for...
If that doesnt work look in your routes and see if TGAR is set 01. If so go in to rdb and out the tgar xnn
JC Walters
2K Communications Inc.
Columbia, SC
I need to push CPND across a Tie route from a Nortel to a Mitel using ISIG. I belive i need MFC package to make this happen. Any thoughts or suggestions?
JC Walters
2K Communications Inc.
Columbia, SC
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.