Both T-1 modules should be set to Loop, this means take your timing from the CO providing the service and not another T-1 in the PBX. Even when you have two T-1's or two PRI's from the same vendor they should each be set to LOOP.
Legend or Magix will not support NI1 or NI2
If PRI switch is DMS100 or DMS 250 request the protocol NTNAPRI if vendor says they only have NI1 or 2 ask if they can emulate a 5ESS with AT&T Custom protocol, the switch tech can do this immediately, then set your switch type to 5ESS.
Set system A time while speaking with user of system B,to ensure accuracy.
Print the error reports for both systems for 2 days to determine if the ckt drops at the same time every night.
I suspect some component in the PRI providers network is running some routine, maintenance synch with...
If all programming is correct I would say it is the protocol from the vendor that changed with the new vendor.
Check the T-1 settings with provider records PRI ckts should be B8ZS ESF.
Check with vendor for protocol used
I would check the call ans service operator ext in merlin mail chances are it is 768 change to 6055.
Also check the class of service for 6055 it should be the same COS as all other regular mailboxes if you want people to be able to transfer to it just like any other mailbox from auto attendant...