hi
system md110 bc9- 1 lim,4 magazines,5 tmu boards ,1 tlu 76/3 active.
kindly advise the cause of congestion problem for internal calls and externals for 1 lim
system equiped with 5 tmu boards enternal extensions are up to 400 ext.
external trunks using 30 lines cas tlu 76/3 and tlu75.
tmu...
hi
kindly advise activation of tone insted of external music source"parval=1,parnum=7".
aspac:parval=177,parnum=7;
system md110 bc12,bc7,pc9.....
using this command only didnot work?
regards
hi
kindly advise the followings:
1-making external call from md110 bc12 sp5 when route is busy ,i get congetions tone insted of busy tone.
how can be change to busy tone?
2-activation mct for saudi arab:
what is the suffix no to be used for analog ext?
Hi All
I have problem with connection ( Q-Interface ) between two BP250 ( MFU ), All trunks gives me blocked.
The programming two sids is:
(Master)
1910 Q-Interface
1911 ETSI/ECMA
1912 Master ( layer 1 master )
1947 Handling of call collision...
Hi ozgur74.
I think any dump in future will given message( LOAD OF STANDBY CONTROL SYSTEM INFORMATION NO DUPLICATED LIM INITIATED ). for remove this the message use ( LAPUR ).
Regards.
Tanks,I have an other message in alarm log:
<ALLOP;
ALARM LOG
IDENTITY: NOT VALID
VERSION: LZY2035101/1/R5A
DATE: 25APR05 TIME: 11:54:10
NO ALARMS IN LOG
END
SPONTANEOUS PRINTOUT
DIAGNOSTICS FROM OPERATING SYSTEM
DIAGNOSTICS FROM LIM...
Hi All.
I have promblem in MD110 (bc9),All extention gives busy tone,and oprator cannot connect with any trunk.
In winfiol alarm log give me,
please help me.
<ALLOP;
ALARM LOG
IDENTITY: NOT VALID
VERSION: LZY2035101/1/R5A
DATE: 23APR05 TIME: 11:22:45
CLASS: 1
320 HIGH CALL RATE
DATE TIME...
hi mikro
thanks ,after changing init string i have manageD to connect to the system modem
then started to read directory
then message (system could not be initialized code:4020)
"i have also tried with init string :S0=1M1
AND I HAVE GOT THE SAME RESULT"
REGARDS
Hi All.
I tried to connected with built modem in BP250,but BMS give me message:
cannot connect to system!
{10980} Modem connection can not be created (ERROR).
ModemInitstring not accepted.
Please help me.
Hi himdp.
I used TLU75 to PPT,( TLP11).and parameters is:
ROCAI:ROU=xx,SEL=713000000000001,SIG=500000000000,TRAF=01151515,SERV=2100000000,TRM=4;
RODAI:ROU=xx,TYPE=TL11,VARC=00000112,VARI=00000488,VARO=00000814;
hi
i ve experience problem with trunk line "system is md110 bc 10"
from internal extension i called to the poblic ."using tlu75/44"
when called party disconnect line while i am still hanging on i can hear disconnction tone from the poblic .
if i dont disconnect the line , trunk line will be...
Hi All
Any body has patch for call duration time ( the call will disconnect after certain time). When somebody from exchange (MD110) seized an external line ( using TLU75) then, I want the MD110 automatically disconnect the line after 10 mentis for example either incoming call or outgoing call...
thank you lalrl,
I solve it. I end (sysn) and initiate in free position and I can dump, but I have another problem GJUL4 blocked,
pls any body help me.
<ALLOP;
ALARM LOG
IDENTITY: GECONEL OIL
VERSION: CXP1010101/2/BC12SP4/R1A
DATE: 15MAR05 TIME: 13:02:02
CLASS: 3
24 FAULTY PCM LINK (GJU)...
hi all
I have MD110 three (lims) one lim is remote my problem NIU2 is blocked login and flash compact (backup) and I have IPU in another lim, I can login , I can not dump on external backup , what shall i do.
pls help me.
<ALLOP;
VERSION: CXP1010101/2/BC12SP4/R1A
DATE: 13MAR05 TIME...
hi
is it possible to have caller id on analogue trunk lines
als on internal analogue lines connected to telephone sets with caller id feature "mfc".
md110 bc 10,11,12.
regards
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.