I have a 2400 IPX with neaxmail ad-120 I know I have all the necessary equipment, but I have no clue on the procedure to take advantage of this feature. I have both dterm series e and I telephones... none have the record button mentioned in the documentation. I am in need of a step by step...
I have two NEC 2000 IPS systems both are 1-PIM systems. What if remove the processor board etc. from one system can I still connect it to the full system as an additional pim if I only install line cards? Is there any true difference besides the hardware between these cabinets?.
I am having problems with call forwarding RNA to voicemail. For some reason my switch is defaulted to six rings before forwarding to voicemail. I need to reduce the amount of rings before forwarding to voicemail. How do I do this in MOC commands? Can anyone help me?
In the past I have been able to setup EVMS (analog voice-mail ports) on older siemens switches like the Hicom 300. I would start by configuring a group of EVMS stations with inband dtmf enabled. These stations would then be added to a hunt group with a pilot #. I would then dial from one digital...
I am having problems with transfer button programmed on an optiset e advance 12 button telephone. I have key number six programmed as a transfer key. Here is my call flow pattern x2000 calls x2001, I go off hook on 2001 and hit transfer button LCD shows transfer not possible. However I can use...
I am currently working with an ip telephone and trying to get it to call a digital set in another location but on the same network. When I call the digital set from the IP phone I cannot here the voice from the digital set. It appears as if I do not have a voice path setup. I was told I needed...
Does anyone know of a way to delay when the CPID is being sent across to anothes statation with standard 2? What I want to do is somehow add a pauuse before the Call Party Id is sent.
OK, I must correct myself. My issue is that I can not get any of the cards in pim 0 to go OPE status except the PW55 and sw10 card in that pim. If I make busy the the SW10 card all th LEDS on the line cards will lite solid green. I have also noticed that my cpu LED (pim ope) in not on.
I have a one pim cabinet and some circuit cards I would like to install. I can login to mat and see all the commands, but have no clue on which forms I need to fill out to add the appropriate hardware. I have set the time and date using ATIM which is the first step in the installation manual...
I have a NEC 2400 IMX with MAT and I usually login with no entry for username and password. This has worked well for as long as I can remember. I also have a NEC 2400 IPX which uses MAT as well, unfortunately I cannot do the same with this switch. I can login and connect without these entries...
I have a hipath 4000, but the analog stations are not sending tones or pulse when a keypress is done. I have a ring genarator card Q2468 and the SLMA card Q2246.
I currently have a gateway programmed with
Maintenance ip address 192.168.1.16
Maintenance Subnet mask : 255.255.255.0
Voice ip adress: 192.168.1.16
Voice subnet mask: 255.255.255.0
Route Net Table
destination gateway
192.168.1.0 192.168.1.16
Route Host Table
destination gateway
127.0.0.1...
I am logging in to the gateway card with Username: ITGADMIN
and Password: ITGADMIN
I am logging in to the OTM application with Username: Administrator and a password configured for that pc
1) I have a 32 port media card installed in slot 6 of a 1 cabinet system. I configured the IP address for the system active ELNK Ethernet interface (LD 117) and it is enabled and active .I have created a zone (zone 0) with the default bandwidth settings and have verified that it is enabled as...
I m trying get familiar with doing various types of input and ouput with the parallel and visual basic 6. I have the inpout32.dll but have no idea of how to use it.
If anyone has any code samples or tutorials it would be very helpful thanks.
I am basically looking for some source code samples to write to an access database I have created. I'm having a ton of trouble with the infamous Access 2003 unrecognized database format via the data access control. Yes I have downloaded all the necessary files SP6 and MDAO 2.8. I want to bypass...
I have tried both of these responses with no luck when I use Set dbInvt = New ADODB.Connection or whatever Set gets flagged as an invalid outside procedure.
I have also downloaded SP6 and MADO 2.8 Library with no results.