  1. notsniw

    Dbc 4220 4222 4223

    Hi, I ve bc12 sp6 two lim system. This telephones sometimes suddenly to give a dial tone. 4220 ROA309208 R3C CAA1580025 R3K 4222 and 4223 ROA309201 R4B CAA1580026 R3S CAA1580027 R2C CAA1580028 R2B CAA1580029 R2B ELU 28 ROF1375334/3 R3B please help me... Thanks
  2. notsniw

    Elu 29

    Hi all, There is a connector on the elu 29 board.What purposeful is this connector? Thanks your help.
  3. notsniw

    Winfiol

    Hi all,I use winfiol 5.2.How i automatic connect to md110. It will connect to md110 at five o`clock and send command.
  4. notsniw

    HL 950

    We will an install bc12 sp6 md110 in two sites.There are between long distance 2km.I want to use wireless solution and hl 950 on all sides.This scenario is it true Does anybody know the solution for this case.??
  5. notsniw

    Ericsson BP150

    Do you have a exu2 in the bp150?If you have a exu2 you are connected the rasc.If you have not from telephone.min dbc 2753.
  6. notsniw

    Ericsson BP150

    hi, prg f1 33333 enter 0201 ent extension number ent 2 ent programmable keys are active 0202 ent extensio number ent 4 ent individual number is active second and then key press
  7. notsniw

    Diversion

    Hi patcher, What s your Application System ? st or ...... We use st standart.Maybe your Application System is true.
  8. notsniw

    Diversion

    hi alchohaz, You are call?ng ?vr,and then you can d?al my phone number.Ivr is transfer your call.F?rst step ?vr to do hook flash.Second step call?ng my phone number.Everything ?s ok. My telephone ?s call?ng,?nternal call.Im not answer the phone.It ?s go?ngto do ma?lbox.But I want to divert...
  9. notsniw

    Diversion

    Hi all, We have MD110 BC12 SP 6 system. We want to make call diversion , according to the origin. The CDIV parameter that we used is "111151311" This is working if the call comes directly to the diverted extension.System can seperate the internal and external calls. But, if the external call is...
  10. notsniw

    Old GJUL4 in BC11 ?

    Hi all, There ?s a same problem bc12 sp6 2lim system. TIME DATE ERROR CODE 11:54:48 11APR05 H'41 INTER LIM SIGNAL LOST - MISMATCHING SEQUENCE NUMBER BRANCHVALUE = 0000000C ENTER SWSW B-LEVEL SIGNAL *************** (H'0000) FROM ****** (H'000) EXE A IN LIM...
  11. notsniw

    niini fails - BC12SP6

    hi, I tested your problem my laboratory. <niini:dir=628,name1="abcd",name2="defg",info="Test"; EXECUTED I think your problem is licence file.
  12. notsniw

    TMU

    Hi all, What is the max number of tmu board in the one lim? for example 1tmu for 200ext
  13. notsniw

    clock malfunction

    thanks patcher,i will test our system..
  14. notsniw

    clock malfunction

    hi all, i connected the public isdn to md110 bc11.md 110 is slave and other site (public exchange) master.Everything is ok.I receive clock other site (public exchange).No alarm in the system.Equipment position 1-1-00. At the same time to add one card (tlu76).The position is 1-1-30.Tlu 76...
  15. notsniw

    Data Link Alarm

    Hi all, I connected the Isdnpri to public exchange.(ISDN PRI) parameter is, RODAI:ROU=6,VARC=00000130,VARI=14400000,VARO=04014000,TYPE=SL60; There is a alarm.Alarm code 303.Data link alarm. What is the Data link alarm (code 303)
  16. notsniw

    RAM

    Hi all, BC12 isn't working 32mb dram.You know.It works 64mb. I put the 32 *2 mb edo ram in the lpu5.D?splay show 1000.memory faulty.I don't find 32*2 mb dram. What kind of ram ? use ?n the lpu5 board?
  17. notsniw

    dublicated control

    yes it is a new installation. for the customer acceptance we tested redundancy by pulling out the lpu5 of the EXE magazine. The system is BC12 SP6.We checked all the cables one by one.also all the boards are working. did you test redundancy by pulling out the lpu5 board before? thank you
  18. notsniw

    dublicated control

    hello everybody, dublicated control is not working. for testing firstly we use dcssp and be sure that dublicated is working correctly. then we pull out the lpu5 of the executing side. stand-by side bacomes executing side after 15 seconds we can take the dial tone again. until now everything is...
  19. notsniw

    voip on the analoque trunks

    Hi all, System bc12 sp5, I want to calling on the voip.My national number 009022422335555.so im dialing 009022422335555.But b12 system first dialing the voip centre (7 digit)and then pause customer number (10 digit) and then pause customer password and at last 009022422335555 customer number...
  20. notsniw

    Replace with ipu

    Thanks for help