Hi,
I ve bc12 sp6 two lim system.
This telephones sometimes suddenly to give a dial tone.
4220 ROA309208 R3C
CAA1580025 R3K
4222 and 4223
ROA309201 R4B
CAA1580026 R3S
CAA1580027 R2C
CAA1580028 R2B
CAA1580029 R2B
ELU 28 ROF1375334/3 R3B
please help me...
Thanks
We will an install bc12 sp6 md110 in two sites.There are between long distance 2km.I want to use wireless solution and hl 950 on all sides.This scenario is it true
Does anybody know the solution for this case.??
hi,
prg f1 33333 enter 0201 ent extension number ent 2 ent
programmable keys are active
0202 ent extensio number ent 4 ent
individual number is active second and then key press
hi alchohaz,
You are call?ng ?vr,and then you can d?al my phone number.Ivr is transfer your call.F?rst step ?vr to do hook flash.Second step call?ng my phone number.Everything ?s ok.
My telephone ?s call?ng,?nternal call.Im not answer the phone.It ?s go?ngto do ma?lbox.But I want to divert...
Hi all, We have MD110 BC12 SP 6 system. We want to make call diversion , according to the origin. The CDIV parameter that we used is "111151311" This is working if the call comes directly to the diverted extension.System can seperate the internal and external calls. But, if the external call is...
Hi all,
There ?s a same problem bc12 sp6 2lim system.
TIME DATE ERROR CODE
11:54:48 11APR05 H'41
INTER LIM SIGNAL LOST - MISMATCHING SEQUENCE NUMBER
BRANCHVALUE = 0000000C
ENTER
SWSW B-LEVEL SIGNAL *************** (H'0000)
FROM ****** (H'000) EXE A IN LIM...
hi all,
i connected the public isdn to md110 bc11.md 110 is slave and other site (public exchange) master.Everything is ok.I receive clock other site (public exchange).No alarm in the system.Equipment position 1-1-00.
At the same time to add one card (tlu76).The position is 1-1-30.Tlu 76...
Hi all,
I connected the Isdnpri to public exchange.(ISDN PRI)
parameter is,
RODAI:ROU=6,VARC=00000130,VARI=14400000,VARO=04014000,TYPE=SL60;
There is a alarm.Alarm code 303.Data link alarm.
What is the Data link alarm (code 303)
Hi all,
BC12 isn't working 32mb dram.You know.It works 64mb. I put the 32 *2 mb edo ram in the lpu5.D?splay show 1000.memory faulty.I don't find 32*2 mb dram.
What kind of ram ? use ?n the lpu5 board?
yes it is a new installation. for the customer acceptance
we tested redundancy by pulling out the lpu5 of the EXE magazine. The system is BC12 SP6.We checked all the cables one by one.also all the boards are working.
did you test redundancy by pulling out the lpu5 board before?
thank you
hello everybody,
dublicated control is not working. for testing firstly
we use dcssp and be sure that dublicated is working correctly.
then we pull out the lpu5 of the executing side.
stand-by side bacomes executing side
after 15 seconds we can take the dial tone again.
until now everything is...
Hi all,
System bc12 sp5,
I want to calling on the voip.My national number 009022422335555.so im dialing 009022422335555.But b12 system first dialing the voip centre (7 digit)and then pause customer number (10 digit) and then pause customer password and at last 009022422335555 customer number...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.