  1. kenkds

    Clocking Questions

    Hi Jim, System One Only has the point to point T1. In System one it's Slot 05. System Two has the Point to Point in SLY 05, a PSTN PRI in Slt 07, A PSTN in SLT 08. From 13:00 13:30 MIS 193 SLP 030 ES 009 BS 008 SEC 000 FS 000 ERROR LOG Last 99 System Errors: Message...
  2. kenkds

    Clocking Questions

    Thanks Jim for the response. Both T1's are from a local provider. The reason for two t1’s is for handling a fund raiser telethon twice a year as well as redundancy should the PRI drop out. I'm looking into the clocking because I'm taking over 255 mis alignments as well as 80+ slips an hour...
  3. kenkds

    Clocking Questions

    Hi Everyone, I need some help on setting up clocking on a networked Merlin Legend to another Merlin Legend through a point to point PRI. System one has one T1, slot 11 going to system two slot five. System two has two additional T1's slot 7 which is a PRI and slot 8 which is a NetFlex T1 setup...
  4. kenkds

    OutBound Caller ID Over Networked PRI Not Working

    Hi I have two switches networked through a point to point PRI. Site 1 has a PRI as well for incoming and out going calls and site 2 routes over the point to point PRI and out of Site 1's PRI. When a call originates out at Site 1's PRI, the caller ID that people see on the receiving end...
  5. kenkds

    SSA Buttons

    No, this switch has just one operator assigned on 1/1. This is the first I've seen this.
  6. kenkds

    SSA Buttons

    I have a Merlin Magix 3.0 Processor with 024TDL in SLT 1 A 024TDL in SLT 2 and 016T/R in SLT 3 and an 800 GS/LS-ID in SLT 4. I'm trying to add a SSA button to a secretarial station. The secretarial station resides on the first 024TDL and the extension I want to add to her phone resides on the...
  7. kenkds

    VM Intergration Issue with a Coverage Button to a Phone

    Hi Merlinman, can you shed any light on this one?
  8. kenkds

    Point to Point down every morning still !

    Had a similar problem with a point to point T1 which was a Telco problem and not a switch problem. Install a loop back plug in your 100 DCD cards and see if they loop back. Run tests under maintenance and see if you have errors. Check and replace your patch cables. Bypass all of your CSU's...
  9. kenkds

    VM Intergration Issue with a Coverage Button to a Phone

    I've installed a new Magix 4.0 on a site which I've done many times before with previous versions, setup coverage group 30 and calling group 770. Added the 8 members to my calling group set calling group for integrated VM and tested every thing works great until I add a primary cover BTN to an...
  10. kenkds

    T1 Dropping Digits

    Not busy at all the calls were failing somtimes with just one call coming in. I do have another site that this may be an issue through. It is two Legends networked with a point to point PRI which the host switch accomodats two additional T1's for access to the outside world going They have been...
  11. kenkds

    T1 Dropping Digits

    I've tested all the boards and controllers and the 400 GS/LS TTR failed the internal Loopback test. The error was 00 00 00 04 00 00 00 00 03 03 03 03 03 03 03 03 I kept the board busied out and made a multiple test calls and so far so good. Thanks for the help with this problem. It's great...
  12. kenkds

    T1 Dropping Digits

    How would you test TTR's? The current config on the switch is: SLT 0 - CKE3/HD 00/ V14.2 SLT 1 - 008 MLX/ HD 01/ Firm 09 SLT 2 - 800 DID/ HD 00/ Firm 80 (NOT USED ANY MORE) SLT 3 - 100 CSU-DSU/HD 0A/APP 18/FIRM 91-(NOT SURE WHY IT'S REPORTING LIKE THIS) SLT 4 - 016 TRR/ HD 50/APP 22/FIRM 12...
  13. kenkds

    T1 Dropping Digits

    Have a service provider delivering me an integrated T1 for voice and data. My first 16 channels are set up as 2 way Tie Trunks / TT /Wink Wink / E&M type 1s / with ansSupvr at 300ms and disconnect at 300ms. The remaining is set as unequipped. The T1 is set for ESF / B8ZS / Rob_Bit / LineComp...