You need to point your server # 1 to IP address of NTP server source and point the other lims/servers to the ip address of server #1 which is the master. In this case the system clock is synchronize.
Use Putty communication software to connect to MGU and use the login and password given by agramkze above. Make sure the ip address of your pc is in the same network as the MGU.
aau2,
You can do it in two ways;
1)Make a terminal connection to the USB port in the front of the MGU.Use cable TSR 899 135/1, which is a USB to D-Sub cable, plus a 9pin D-Sub female to female adaptor.Use a terminal program, for example, kermit. Baud rate is set to 9600 bits/sec, 8 data bits...
I still can't find the cause of the problem but I am sure it is something to do with our office data. I tried removing all the cordless programs(CTLMP,CTLP & CXHH)using LAPUR & reinstalling
again the same but the problem still there. I guest I just have to
do new in-house switch installation.
I would like to correct the info that I had given about the problem. The problem is not related to compiling error from previous release to tsw sp6 or sp7. I think it has something to do with some data being inputted to the pabx. If we program only dect phone extensions(cx command) the DT690 can...
As I said the DT690 is not working on tsw sp6 & sp7, it may be a compiling error from previous sw released to tsw sp6 & sp7. We are using Application Standard here in our area.
rokane
I discovered the problem, it was software fault in standard tsw sp6 or & sp7. When I downgraded the reference switch to tsw sp4 the DT690 & DT570 can now both be subscribed.
To all who responded to my post, thank you so much and more power to each and everyone in tek-tips !
rokane
whosrdaddy,
Everything is alright there is no alarm. I can subscribe the DT570
as before but not the DT690. Since it not working with elu31/1 I will try to get ELU31/3.
rokane
whosrdaddy,
We tried mx-one tsw sp7 but the DT690 still can't subscribe. The DT690 firmware is 3.0.5 . The option to downgrade the software of DT690 to 2.8.18 is not posible at this time as we don't have the PDM/CPDM unit yet. Any other solution pls!
whosrdaddy,
Thank you very much for the information. The DT690 has 3.0.5 firmware so probably I have to upgrade the switch to sp7. I will try it in our lab & let you know if the problem is solve.If not, I will try other option like downgrading the firmware to 2.8.19 as
mentioned by doctor if SW...
doktor,
The main problem is we can't subscribe the DT690 cordless phone to
MD110 TSW sp6 using ELU31/1 but for DT570 it is okay. My main concern is that we have customer running MD110 TSW sp6 with cordless system. They are using ELU31/1 and planning to buy DT690 but if this unit can't be...
Does anyone knows any issue about it in MX-ONE TSW sp6? I can subscribe DT570 to the same ELU31/1 but I can't if DT690. But using BP250 switch... both cordless phone works(can be subscribed). I am using the same base station bs330. Do I need to use ELU31/3 in MX-one? Your input is highly...
I just wanted to know what is the maximum capacity of the compact flash that the NIU2 can handle. The reason for this is there are no more 128mb & 256mb available in the market...mostly is 1gb,2gb and up that are available. Can I use these higher capacity CF on niu2?
thanks
Can someone pls tell me what is the minimum memory requirement for ESU board loaded with TSE 3.2 sp3 software.
I am try to load the software but it won't complete but when I used the TSE 3.1 software the loading is completed & with no problems. My ESU has 512mb memory only.