If you are worried about it, pick a spare digital TN, plug a 2008 in and program the phone there and test it.
If everything is ok you have two options rejumper the exsisting phone to the new tn or out the 2009 and copy the info from the new tn created.
DFB
Thanks to all,
Its not the DN's I'm after, its the Pstn Number I dial to get to them DN's.
Ive been told to look at CLID in ld 21????? I'll try that as well.
I have an opt 11 that when an internal call hits a disabled phone it returns nu. However an external goes to music on hold.
There are no 2250's programmed. My question is where do I look to find the call routing of the external call????
ssck 0
ENBL
CLOCK ACTIVE
CLOCK CONTROLLER - LOCKED TO SLOT 1
PREF - 1
SREF - FREE RUN
AUTO SWREF CLK - ENBL
NO ERROR
IP DB PORT 1 DSBL
IP DB PORT 2 DSBL
IP DB PORT 3 DSBL
IP DB PORT 4 DSBL
CALL SERVER CLK SRC: CC
Thanks John I know I can procomm it but if I can stop the counters failing by "upping" them in the short term I dont have to tie my pc up.
PerryPJ if I goto change these in 73 I get this
MEM AVAIL: (U/P): 519848 USED U P: 585574 74225 TOT: 1179647
DISK RECS AVAIL: 445
REQ prt
TYPE...
I have an BVP error at a remote site, I can't get there until next week. The Tie link keeps going down after erroring See below. I know I need to sort the fault out, but in the meantime I am dialling in every hour to reset the counters to stop the link going into maint or nnc.
Is there any way...
I would have thought so, but this is Nortel...
It don't appear there. It says service stopped and it should be easy to start (you would think).....I cant find the bloody thing.
I have had OTM for a year, we have just linked it to our internal DECT system.
Dect is accessable and working fine on the server.
We can access everything via the intranet, (DECT Web alarm, DECT Web maint) but the Web Dect Application hangs.
I noticed that under the OTM status, DECT JVM: is...
Getting these errors on one end of a link:
% TOTAL 24HR BPV - 000000000 000000004 000000005 000000065
% TOTAL 24HR CRC - 000000003 000000000 000000000 000000000
% TOTAL 24HR FAP - 000000000 000000000 000000000 000000000
% TOTAL 24HR SLPREP - 000000000
% TOTAL 24HR SLPDEL -...
Thanks for the help looks like bootp kicked in when the miran was reset. It is functioning correctly but with the above error. I will visit site and log into the front to see if I can disable the network.
John Can't see AML in ADAN (print out below) the only 7 is TTY 7 this is disables and I cant enable it?? (print out Below ADAN data
ADAN HIST
SIZE 50000
USER MTC SCH BUG
ADAN TTY 0
TTY_TYPE SDI
CAB 00
CARD 00
PORT 0
DES MAINT.MODEM
FLOW YES
BCST NO
USER MTC SCH BUG...
I have a constant error message AMLM024 07 on an OPT 11C Rls 21 v3
To rectify the fault I have gone LD48 stat AML and get no reply just
LNK000
.stat aml
.
Any Ideas how to supress/correct this message.
I am new to procomm and have written the following script with the help of this forum.
The Idea is to dial up each of my remote Meridian sites and save the history file.
It will dial the first site and execute the dialup, logon and print the history file and clear down, the next site
it will...
I have two locked apps that I cannot access (app builder says)
" the system could not load the application from the server please check the connection and try again"
All other apps work fine but the sequence of numbers that appbuilder gives are now out of synch (its reissuing 1011 which is...
Thanks for the reply John,
I've changed the CLS on both phones to NAMD DDGD CLBA DNDN CNID CNDD.
But still if you CFD the phone to another set it displays originating digits.........
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.