I have a 3com 4400 switch that has port 1 configured as 100 Full duplex and it is attached to a linux box network card that is a gigabit 10/100 card also full duplex.
I am getting CRC erros increasing by about 10 to 15 every time it refreshes(about 6 secs).
Does anyone have any suggestions as to...
Thank you Ace, I meant know disrespect.
I have a DID 431 0004 which pulses 7003 and there is an ACDN for 7003 which NCFW to 7000 which is where the auto attendant resides. I did not set this up just trying to figure it out.
I try to change the ACDN NCFW to 94054083 which is my DID i want the...
It just goes through some menu options but I dont even care about that. I just want to forward it right from the switch to the external number without the AA.
thanks
Hi , I have a number terminating on my PRI into my 61C
555 0004 and I want to call forward it to an external number 405 4083.
I use to do this through creating an ACDN and NCFW but it wont let me creat an acdn for 0004 I guess because of the leading zeros?
0004 does terminate on an auto...
Does anyone have any examples of prioritizing voice over data utilising 3com 5009 routers?
Looking for a starting point- first time trying this setup.
thnaks in advance.
wd
it worked fine until we tried to switch CC card last night. We never touched the 5th card where the CC daughter was.
That is why I thought today putting a live T back in the 5th card we would be able to get it back to the way it was yesterday
CC 0 pref 5
CC 0 sref frun
there seems to be a CC 3...
here is my counters
I also reset them. I also included my ssck 0 and the DDB in ld 73
see below:
.lcnt
PRI TRK LOOP 3
TRSH CNT:
BPV -000
SLIPD -000
SLIPR -000
CRC -000
LOSFA -000
OS_BPV...
Thanks for the quick help guys,
I do have a working T1 back in card 5.
I have been resetting the counters.
My main concern (I think) is to get the CC pref set back to card 5 to fix what ever got screwed up last night.
the 61 is fine and does get its clock from telco.
I cant seem to change the...
Hi,
i have a nortel 61 C and a remote 11c
There is a TIE line between the 2 loop 25 in 61 to loop 8 in 11C.
The pref clock source for the remote was on Card 5
That t1 came out of service so we tried switching the clock source to another card not realizing the piggy back CC was on that card. We...
Hi,
No CDR pack in ld 22
Here is the ACDN: and it looks like i do have reports turned. I do have symposium as well.
REQ
OVL000
>ld 23
ACD000
MEM AVAIL: (U/P): 4975783 USED U P: 2357677 121259 TOT: 7454719
DISK SPACE NEEDED: 212 KBYTES
2MB BACKUP DISKETTE(S) NEEDED: 1 (PROJECTED LD43...
Hi acewarlock , I have done no real reporting from the 61C.
Could you elaborate?
I don't believe we have the CDR package.
Any other Thoughts?
Much appreciated.
Wyles
Thnaks John
I have rcnt both loop 5 and 6 as i am having the problem on both loops.
I had to disl and enll both loops to get the channels anabled again but both Ts are still in a Yellow Alarm state?
Any thoughts?
Thanks,
Wylie
I keep getting the following errors
DTA 005 6
DTA 007 6
Then when I stat the loop 6 I am seeing a message at the Top indicating "REMOTE ALRM OS LIMIT EXCEEDED"
And it usually Disable the whole LOOP.
I can re enable the loop by
DISL 6
and then ENLL 6 but it will happen again in an hour or so...
The way we have it setup right now is T1 trunks connected to analog lines thru a dialer.
The agent needs to conference in a third party vendor to the customer and then drop out but right now if the agent drops out everything is gone.
I am not sure how the T1 is configured (loopback or...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.