Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations IamaSherpa on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. robinz

    Users can't see Domain Controller

    Now fixed, for info... The server had 2 NICs fitted and has always reported that a device with a duplicate IP address was visible on the network. We disabled one of the NICs and rebooted and everything started working and we were able to repair the trust. The unexplained bit is why the dual...
  2. robinz

    Users can't see Domain Controller

    Our Domain Controller (W2k Server SP1) in our mixed domain crashed for no apparent reason and since then (even after a number of planned reboots) it does not seem to be advertising itself as a DC because other machines complain that the DC cannot be reached. This has caused two significant...
  3. robinz

    Configuring named & sendmail

    Hi guys, Thanks for our posts. Mike, I see what you're saying but, at the exchange box, I've configured it to supposedly handle both the SCO and AIX boxes by adding both of the appropriate ip addresses. I agree that it is beginning to look as though the AIX is configured OK and the problem is...
  4. robinz

    Configuring named & sendmail

    Hi Mike, Thanks for replying. Yes, I can ping using the *name*. To direct traffic I editted the following : Add *name* and IP address to /etc/hosts. named.data - line added as follows : *name* IN A *ip address* named.rev - line added as follows : 3 IN PTR *name*.*domain*...
  5. robinz

    Configuring named & sendmail

    We are running AIX 4.2 on an RS6000. We currently have AIX successfully sending messages across to our MS Mail server using sendmail & named. We are in the process of upgrading to Exchange 2000 on a different server and would like to add the new exchange server as an alternative destination...
  6. robinz

    Terminal Connection to 64 port Async Controller

    I am assuming you have standard IBM RJ45 to 25-way D type interface cables. If so, this is what works for us : 1 - cable shield - 1 2 - txd - 3 3 - rxd - 2 4 - rts - 5 5 - cts - 4 6 - dsr - 20 7 - gnd - 7 8 - cd - 20 20 - dtr - 6 and 8 If you don't have std IBM cables then I have details of...
  7. robinz

    Fails to create print queue

    Thanks Chuck, that did the trick! Robin
  8. robinz

    Fails to create print queue

    I'm running AIX 4.2 on an IBM RS6000 System 370 fitted with a 64 way concentrator. I would like to install print queues for various simple text printers but when I attempt this via smit I get the following error : 1800-106 0782-626 Opening the ODM class "sm_cmd_hdr" failed (odmerrno...