Cheers this does seem to be the case though it does seem a bit unclear from reading endless documentation and help files. Gu8es it's in the wording as the help for the client push installation says it will 'install on clients that are discovered but do not have an SMS client installed. Well in...
Thanks for the reply
I had not got as far as modifying the login script. I configured the Client Push Installation properties and enabled it but I thought the client installation did not start unless you right clicked on a collection or query and selected Install Client. Reading the...
Hi,
Installing SMS 2003 into a single site which is currently SMS 2.0, using new hardware and site code. Configured Client Push Installation method but did not run the Client Push Installation wizard to start deploying clients. Despite this SMS started upgrading clients! We had planned to...
Cheers figured it out in the end. I was trying to send an email to a pickup directory on another server using a copy to \\servername\c$\inetpub\mailroot\pickup. Perfmon doesn't have access rights to access C$ on another server by default unless you specify an admin account to run the service...
Hi
I'm not too sure what you mean by using VB? I've got a job in a couple of weeks to replace two DHCP servers and was going to rely on the process that they will try to renew the lease from a server which is no longer there an then get a fresh address from the new servers. I have thought about...
Not quite the client will keep the IP address of the server it obtained the address from. It will attempt to renew the least from this server until 87.5% of the lease time is reached when it will drop the lease and attempt to get a new address from any DHCP server it can find.
Paul
Thanks for this. I had tried this util from sysinternals before but found that it left the BE agent in an unstable state which could still only be solved with a reboot. Restarting the BE service didn't help. I did go through and close any handle that referenced vsp files or the OFO cache folder...
Yup tried all these solutions with no luck. Veritas are out of ideas and I have had a case open for months with them. If I find anything new I'll post it as I have another Veritas technician calling me from the States tomorrow to try and fix this.
I have the same problem on the majority of our servers. The OFO cache file is not deleted at the end of the backup and it becomes locked. This means the following backup OFO fails because the previous OFO cache file is still there. The only way to remove is to reboot which is not a viable...
Using Version 9.0 and I cannot merge Arcserve tapes into my database though I could previously. I keep getting catlogue errors. Veritas have helpfully suggested I trash the database and start again. The utility tools do absolutely nothing so I am going to have to start again with the database...
Same old problem here but kind of good to know there are other people stuggling, for what its' worth my experiences are:
I am using Arcserve 6.5 build 620 and never had this problem using a variety of DAT/DLT drives. It started when we got Compaq SDLT ML5026SL tape library which has been...