  1. rednaxela

    Switching number identification

    Lalrl, Which patches are you talking about ? We have a BC9 at EOL.. Further, we're in the Netherlands. Sorry Rfboi, 142 doesn't work.... Any idea ?
  2. rednaxela

    Switching number identification

    Can someone tell me if it's possible, for example with a predefined code like *something# to block your call identification per call to external callers when the identification is open system wide ? We would like the option to block certain numbers from viewing caller identification when at...
  3. rednaxela

    Dual Ringing

    FCPLI, Is this an external application ? Would it work with BC9 or 10 ? Could you tell me more about it ? Thanx already....
  4. rednaxela

    Conference-beep

    We have them all, BC9 and BC10 take your pick... I'll check the forum, thanx....
  5. rednaxela

    Conference-beep

    Can someone tell me of it is possible to get rid of the beep that the MD generates every 20 seconds during conference calls ? Thanx already
  6. rednaxela

    CIC - Conferences

    Does anyone have experience with the CIC-callcenter solution from Interactive ? Is it possible to let users set-up a conference ? Through a voice-responce system for instance ?
  7. rednaxela

    unable to delete extension from call pickup group

    Maybe the reset of the Call-pick handler may help... RFPUI:LIM=XX,UNIT=GPP; Where the LIM is the correspondig lim for the group.
  8. rednaxela

    LIDAP BC9

    Thanx SYAR, Thought so, but wasn't sure.....
  9. rednaxela

    LIDAP BC9

    Hey all ! Can someone tell me how to extract the lidap-file for BC9 ? I want to know how many OWS-licences we have on our MD. Thanx already........
  10. rednaxela

    OWS Problem

    Which PU's did you restart ? Did you do OLP1S1/DOR/DOM ?
  11. rednaxela

    ALU 2

    Thanx LALRL ! So far so good: <aldip;ALARM DISTRIBUTION DATE: 26FEB03 TIME: 16:28:14 IODEV FUNCTION FORMAT INT/CLA DATE TIME ALARMS ALARM PRINTOUT ASCII 1,2,3,4 ALARMS HEART BEAT ASCII 00:15 26FEB03 16:28 END I've received some...
  12. rednaxela

    ALU 2

    Isinor, I'm doing something wrong :) Any tips ? It's no problem that I've used the same port for MML-IN usage ? <IODDP;I/O DEVICE DATA NODE IODEV/SUBFS BPOS/EQU SIPOS TYPE/USAGE STATUS AUTH SYSN - 001-0-60 - - IN SERVICE...
  13. rednaxela

    ALU 2

    Hey Isinor! Maybe you can finetune the rough guide for me. I've created an IO-device but I can't set the output: SYSN ALARMS 001-0-60-4 - NETWORK/OUT IN SERVICE ALAPI:IODEV=ALARMS,CLA=3&4;NOT ACCEPTED ALARMS NOT INITIATED What does this mean, ALARMS not...
  14. rednaxela

    Calvi TR

    Hey all ! Can anyone share some information or user-experiences with the Calvi Traffic-recording system ?
  15. rednaxela

    Night diversion to other site

    Hey Patcher, Thanx, works like a charm !
  16. rednaxela

    Night diversion to other site

    Okay, here it goes: 2 stand alone-sites BC10, no link whatsoever. How can I divert calls to the main number of the first lokation to the second when the operator set's the OWS in Night-mode ? (there's no option to get an external number in the nightdiversion settings) Even more perfect would be...
  17. rednaxela

    Ericsson MD110 Spare Parts

    Hey Bartjo, how do u know Candour ? It is not quite known, and seeing how u put their name and site first I can't help thinking there's a relation. B.t.w. how's Gilbert ?
  18. rednaxela

    Scheduled log-on to BC10

    Is it possible to scedule a connect to a MD (via FTP or Fiol), run a script, log-out and connect to the next one ? I have a macro-script which logs on in BC10 but it won't run unless I open a channel by hand.
  19. rednaxela

    WinFIOL

    I have Winfiol 5.2 and it operates without any problems on Win2K.