Hi,
I like to re-direct on a incomming a-number on a BC11 system.
What I like to do is connect a specific a-numbers to a specific extension or route.
If external number 0123456 calls in to the PBX it will be connected to extension 333.
But all other external are routed as usual.
Can NUTRI be...
The pinouts for this serial link can be found in Alex.
Look in the:
"Extra facilities without commands"
"Access Agent"
"Installation"
"Installation Instruction"
I hope this helps you.
/MDatHome
Hello,
I have a problem.
I need to connect 2 MD110 with ISDN.
This is on a railroad where the they like to have there own transmission.
If I have a TLU76 (30B+D)
there is a limit of the cables stated in Alex:
- 180 m if using a 75 ohm coax. cable without repeater.
- 260 m if using a 120 ohm...
This is my sugestion to you:
- Backup should be done automaticly every day. (DUFQI)
- Replace HDU every month.
(have at least 3 HDUs to switch with)
Store the "not in use" HDUs in a safe.
- Do a check every day for alarms and history logs
and clean them up after solving the problems...
Also make sure that you do not have a firewall that stops the traffic.
If it fails to logon, do check with IPEXP if the MD110 think it has register the phone.
This is an example with a firewall that gives totaly wrong IP:
ipexp:dir=all;
IP EXTENSION DATA
DIR IP ADDRESS RAS PORT CS...
Hello all,
I have got a used A1000 RAID rack and it worked for about 2 days then it stoped to work after a power failure.
I have connected to the serial line on the back to see whats happening.
It starts but ends with some warnings
and then nothing happens.
Send <BREAK> for shell access or...
Hello all,
I have got a used A1000 RAID rack and it worked for about 2 days then it stoped to work after a power failure.
I have connected to the serial line on the back to see whats happening.
It starts but ends with some warnings
and then nothing happens.
Send <BREAK> for shell access or...
I had the same problem.
This patch forces the NIU to use SCSI ;-)
PCASI:UNIT=IOH,CI=SCSI,REV=4-R4A,IA=3E0,RA=3F4,BYTE=0;
MOVE.B #2,($39,A6);
MOVEA.L ($2C,A6),A4;
END;
!A;
PCACS:UNIT=IOH,CI=SCSI;
Y;
PCCOS:UNIT=IOH,CI=SCSI;
Y;
Hello all,
Some one told me that there exist a additional program unit for BC11 that allows some sort of groupcalls to multiple members at the same time.
Trunk calls was working too.
It was possible to get the mobile phone ringing at the same time as a extension inside the PBX.
Is there...
Hello, njohn343
Yes it is possible to find out the IPEI if it is not shown on the DECT phone.
First start a unit trace on CTLP:
<STUNI:UNIT=CTLP,LIM=1;
<STTSI:TRI=1;
Then try to register the dect in MD110 (unsuccessful)...
<STTSE:TRI=1;
<STRAP:TRI=1;
TRACE IND READ RESULT
TRACE...
First of all make sure you have the latest firmware files
on the ELU32 board and the IP-Phones.
If you change the jitterbuffer size you need to restart
the ELU32 board to get it work with the new parameters.
The ELU32 sends the priority in ToS
and the network must be switched (no hubs)
to...