I have been asked to extend a T1 circuit which is no problem, have done it many times. And then at th last minute they add that they want to do a head to head test (1's and 0's Quasi), and that I can use a router, CSU,DSU for this. In my experience the local Telco does this with a T-Bird or...
We are opening a new office and have several Merlin ETR 18D's and 1 MCS12 but no KSU, what model and version of KSU do we need. We wont be expanding to anything more than 6 lines and 8 sets. No voicemail we are using LEC for that.
Im very familiar with Nortel and this Avaya is new to me.
Thanks
I installed a new CICS w/7.1 software today and set the time as usual. About 10 minutes later I noticed the time was like 1am and the date was a day later than it should be (the 18th). So I set it correctly, and again 10 min later the same thing. So I then did a system startup to hopefully clear...
hdtelcotek,
We discovered that a patch had been installed by our vendor (without us knowing) to eliminate "walk aways", in other words if the headset amplifier is turned off and an ACD call comes in it is forced to the phoneset. For these agents who were experiencing the issue we changed their...
We have an opt 81C 25.40B, Symposium 4.2. What is the easiest way to send DN calls (key 1 and 2) directly to voicemail while agents are on an active ACD call (key 0).
We have ACD phones in our main office (in NY) connected to our OPT 81C (in CA) via a 9150 card. We have Agent Greeting installed and working perfectly in our CA office. We just received a request to have our NY agents start using A.G. My question is should the Agent Greeting play when agents...
Yes we replaced the phoneset, outed and rebuilt the TN in PBX, TN in Symposium and rebuilt the user profile in Symp., I guess Ill have to get our vendor involved....
We have an opt81c 25.40B, Symposium 4.2. Something strange started happening about a month ago. ACD calls are presented to the phoneset and instead of coming thru the headset the caller is heard over the speaker of the 3905... I have never seen this before, any ideas anyone?
I am getting complaints of a message "your session cannot be completed" being heard (before the proper greeting plays)by the originating party, when calls are tranferred between departments (via a CDN).
Has anyone run into this?
We have an opt 81C, A.G. 2.0 ver.3.0.6, Symposium 4.2
We have an option 11C in an equipment room that shares a wall with the adjacent suite. That suite will soon be a medical office which will have an MRI machine. So the opt11 cabinet will be about 8 feet the other side of the wall from the MRI, should the magnetic field created cause any...