Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. mrplacid

    IP Office 500 - losing lan connection

    Has anyone experienced this? I have an IPO thats been quite happy for the last month using only SIP trunks until today when calls kept dropping and the IPO was not reachable on the LAN. I have seen reference to overheating in thread940-1668521 and wonder if anyone else has witnessed this. I...
  2. mrplacid

    Sip Trunk WAN Failover

    'Check OOS' makes no difference either way. Not sure I can blame the Draytek on this one as rebooting the IP Office makes it work and not rebooting the router. I can also browse the Internet quite happily when the 3G failover activates. Can anyone recommend an alternative router (ideally with...
  3. mrplacid

    Remote H.323 extension. So close....

    I tried the external extension on the IP Office LAN today but still with the external IP address in the call server and again it didn't work until I updated Draytek firmware (hadn't realised it wasn't at the latest). I thought this was progress but it still doesn't work externally, although...
  4. mrplacid

    Sip Trunk WAN Failover

    Assuming you mean 'Check OOS', it is currently checked. I am not onsite at the moment but will try and test with it unchecked. I need to be careful disabling WAN1 while off site in case I cut myself off!
  5. mrplacid

    Sip Trunk WAN Failover

    IP Office with 5 SIP trunks working well through Draytek router. I have configured a backup WAN using a 3G dongle but the IP Office rejects calls until I reboot the IP Office (when normal ADSL wan is down and backup wan is active). Any thoughts?
  6. mrplacid

    Remote H.323 extension. So close....

    Draytek IP Office side and BT Home Hub remote side.
  7. mrplacid

    Remote H.323 extension. So close....

    I'm struggling with this one too! I have followed all of the steps above but the phone toggles between registering and phone. Monitor: 2152267mS H323Evt: Recv GRQ from 56b1b940 2152267mS H323Evt: e_H225_AliasAddress_dialedDigits alias 2152267mS H323Evt: found number <217>...
  8. mrplacid

    Remote H.323 extension. So close....

    I have followed all of the steps above but the phone toggles between phone and registering. Monitor: 2152267mS H323Evt: Recv GRQ from 56b1b940 2152267mS H323Evt: e_H225_AliasAddress_dialedDigits alias 2152267mS H323Evt: found number <217>
  9. mrplacid

    Uploading a file (contact form)

    Hi I am trying to add an upload file option to an existing contact form. I have tried using persits aspupload but I do not want to leave the current page. My contact form is an include file which currently calls a script for validation on submit and then returns to its calling page if all is...
  10. mrplacid

    Public OLI

    Thanks for your reply. It is not allowed to be witheld and if it goes out as a generic number and the recipient calls back, we have no way of knowing how to answer the call.
  11. mrplacid

    Public OLI

    I have a situation where I need to change the public OLI depending on who is being called! My client makes outbound calls on behalf of various companies that they work for and the OLI needs to be different for each company. Thanks in advance. Martin
  12. mrplacid

    BCM50 Hunt Group Mailbox/Night Service

    I have found numerous threads relating to this but everyone appears to have different requirements! I have multiple extensions with DDI's that forward to VM after hours with no problem. I also have a main number on 4 lines and these lines all point to a hunt group (should I be using a ringing...
  13. mrplacid

    BCM50 Expansion

    I am told by my vendor that the codes are only compatible with v2 and even if I was to upgrade the software to v2, my hardware will not support the built in analogue extensions! They have suggested that I upgrade the software to v2 and then install a digital/analogue extension combi card. Any...
  14. mrplacid

    BCM50 Expansion

    I am told that these key codes are only compatible with v2. I believe I have v1? (bcm_m50r1 1.00.2.04.j) Is this correct and if so, is it just a software issue that can be upgraded or is it the physical hardware? Thanks
  15. mrplacid

    BCM400 '0 for operator'

    Stupid question but where do you set which extension is associated with dialling zero?
  16. mrplacid

    BCM50 Expansion

    Thank You! I can now see from the RJ21 wiring diagram that there are 4 analogue telpehone connections. I have connected an analogue telephone to device 5 (DN 233 Port 413) but it is dead. Am I missing something?
  17. mrplacid

    BCM50 Expansion

    I have a BCM50 currently with 1 expansion chassis containing a Digital Trunk Interface. I need additional extensions but also 5 analogue extensions (modems/fax's). If I add another expansion chassis (I believe I am limited to 2?) would it be best to add a digital extension interface and then 5...
  18. mrplacid

    BCM50 DASS2

    Thanks, worked a treat but I am not sure I understand why!
  19. mrplacid

    BCM50 DASS2

    I have a BCM50 with DASS2 trunks. The trunks are configured with a DDI range on channels 1-12 and a main number on channels 13-16. I can make outbound calls and receive incoming calls on the DDI range but inbound calls on the main number only do half a ring after a long pause and then die! Any...
  20. mrplacid

    SBS 2000 &amp; Firewall/VPN Hardware

    I have an Zyxel broadband router (with IPSec vpn capability) providing Internet accesss to an SBS. I can successfully configure this using 1 or 2 NIC's (I assume with 1 NIC the firewall side of the ISA is redundant?). I am now trying to implement the vpn side of the router but I am struggling...