We have connected 2 magix systems using INA cards at
both ends channels 1-12 DATA 13-23 Voice 24 D-channel
we are doing centralized voicemail can udp calls to and from both sites but are blocked from calling through to the other side be it copper 70 or Flexpath (891)
FROM SITE A
ars table
2...
Phoneguy4u
I'll try that but we could not even send it off a another trunk group ( in this case comes in on AT@T Megacom
800 trunk group 2 as did and we send it back out on trunk group 1 through ars routing which is a copper pots trunk group loop-start ....thanks for all the replys
It sounds like your ars table is blocking the call. With all the new prefixs for cell phones you might check the partitions and make sure the prefixs are listed. You can use "disp ars analysis partition 1 xxx" to check for your prefix...
We have a call center setup where afterhours and on weekends it calls (route to xxxx ..an x-ported extension
with cover remote to offsite ...it works fine with Land
lines but its BLOCKED when trying to use a cell numbers in the cover remote field ...has anyone seen something like this ????? I...
My suggestion would be to make them all wink start and have all your inbound calls be directed by DID or DNIS digits. Outbounds would be unaffected. Worst case scenario is that you have to send some calls to a calling group to ring several phones, but it seems like the way to go.
if it rings...
pbxman
I was able to list bcms agent 2151 from ASA
right on the server PC ....its using a ip connection
to the 8300 it will pull anything
list bcms agent , skill , split with no issues while
in ASA.
marcell55
I will try that first thing in the AM .....this is good
to know as we have...
We have just upgraded our system to an S8300 rel 11
from a prologix rel 10 ....we are now using EAS with
Agent Id rather then bcms login id's
we can list bcms agent xxx and see the data from the
switch but can not get any data from BCMS vu server if we
log on as client on the desktop or right...
We are switching from a release 10 Prologix to an S8300
release 11
we had been using c-lan connection for BCMS Server and
ASA from a workstation using node-names ip , ip-int
ip-services ...data module (ethernet)
my question is :
since we do not have a c-lan or an ipsi card card in the s8300...
WE ARE HAVING AN ISSUE PUTTING A (AVAYA)LKA10
HEADSET ON A 6424D+ PHONE OFF OF IP OFFICE
REL 1.3.37 ABLE TO RECEIVE CALLS ON HEADSET
....BUT NOT ABLE TO BREAK DIALTONE FROM DIALPAD
ON CORDLESS HEADSET .....SO YOU CAN ANSWER CALLS
BUT NOT TRANSFER THEM WE HAVE TRIED 2 DIFFERENT...
Is it possible to have an extension (voicemail) call out to more then one number ...using source number within the user as this case is its a SERVICE afterhours mailbox
source number
P*601
Shortcode *601
tel # 1212xxxxxx,,,,,100## (BEEPER)
grp 0
feature dial
works...
Logged into bash all services were up ....
Tier 3 called into IP600 and put in a couple of patches
12,14,15,22 for release 10 they also did a database
clean up and fix ....stop and restarted the system
I had already done the stop and restart ......
I reprogrammed the ports in order
for...
We have an issue where the Audix picks up and you hear 3 - 4
seconds of silence ....NO Alarms on Ip600 , Audix
busy board a12
test board a12 (Pass)
release board a12
test board a12 long clear (Pass - resolved)
sa trans and did a reset system 4
Audix still picks up and silence...
I have installed a NEC Electra 48 with a voicemail Elite in slot 07 for a friend that wanted to reuse it from another site ( I mostly work on Avaya )
I worked on them awhile ago but can get around logging into x100 or x101 ...also using cosession for the voicemail
*my question is this we have...
I have also installed a NEC Electra 48 with a voicemail Elite in slot 07 for a friend that wanted to reuse it from another site ( I mostly work on Avaya )
I worked on them awhile ago but can get around logging into x100 or x101 ...also using cosession for the voicemail
*my question is this we...
Thanks!
Able to login and set my IP Address
show control interface reflects changes as well
as seeing "IP" displayed on the front LCD
documents say to connect "network" to the back of the
IPSI board (slot #2) but I'm not able to ping ....
able to ping to IPSI board...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.