  1. icstech

    VM Callxpress with F9600

    Tried that and still blowing the serial port Checked the spare DCU port to make sure it was working (programmed it for a MC port with 9600)and got in using direct connection. Reprogrammed for SMDI 1200 an blew the serial port.
  2. icstech

    VM Callxpress with F9600

    Hi all I am having problems with my Callxpress voicemail. I know the intergration is correct. A while ago I noticed that i had to keep on reseting the port. now the port would not reset. After checking the computer hardware found the serial port was defective. Changed the serial card with no...
  3. icstech

    Max distance for a digital extension

    Does anyone know the max. distance for a digital extension? The system is a ICS compact and they want to intall a digital extension to another buliding Thanks
  4. icstech

    BCM 400 AA and Call pilot

    OK Guys A quick update.... the caps were green my provider refused to replace for free. Purchased a new BFT (from a different vendor)and install yesterday, worked and now hopefully upgrading the software
  5. icstech

    BCM 400 AA and Call pilot

    Thanks Guys I will have to check out those Caps
  6. icstech

    BCM 400 AA and Call pilot

    Hi all BCM 400,3.0 status lights 3 to 8 blinking (green) and AA and voice mail not working. Also can not log into Unified manager and call pilot manager. Vendor says need to upgrade to 4.0 but if I can not log in how would I upgrade Thanks
  7. icstech

    12x0 Trunk Module Card 1 not equipped

    Ok here is another update Changed the fibre cable with no luck Backed up the system and did a startup and reset the memory Reloaded the system configuration and still having the same problem Card 1 on the trunk module (port8) stays "unequipped" I am starting to think that you can not put a...
  8. icstech

    Trying to figure out how to adjust time

    you need a T7316 phone to program 7208 will work on smaller systems 3X8 Try Feature **TIME and use password "BASIC
  9. icstech

    12x0 Trunk Module Card 1 not equipped

    If you mean switching the fibre cable for the trunk port, no that I have not done as yet (trunk module has to stay on port 8) I will try that tomorrow as well before I do the restart
  10. icstech

    12x0 Trunk Module Card 1 not equipped

    OK here is an update Finally ordered a new 6 port fibre card and changed one of the combo cards That did not work (tried combo card in both slot 1 and 2) Only thing left to try is a back up and restart
  11. icstech

    12x0 Trunk Module Card 1 not equipped

    Phoneguy427 under module status it is unequipped for card 1. check the test log nothing to do with the trunk module Tried what you suggested with no luck same thing Not seeing that card 1 The only thing is i can see that may cause this now is the 2 combo cards in the system at the same time?
  12. icstech

    12x0 Trunk Module Card 1 not equipped

    phoneguy427 Tried switching the combo cards and that did not work Same problem with the card 1 not showing any lines. The system has two combo cards instead of just one and a normal fibre card. Do not know if this might be the problem where the system can physical only have one combo cards...
  13. icstech

    12x0 Trunk Module Card 1 not equipped

    no but i guees it is worth a try I am going to see if that works I have two in the system I will let you know if that works
  14. icstech

    12x0 Trunk Module Card 1 not equipped

    Yeah I thought about that too and did it a couple of times
  15. icstech

    12x0 Trunk Module Card 1 not equipped

    did that already, same thing, even tried a new 12x0 module yesterday thinking that had to be the problem. Still did not work, this is why I am wondering if it has to do with some configuration of the T1 and trunk cards Any other ideas
  16. icstech

    12x0 Trunk Module Card 1 not equipped

    Phoneguy427 My mistake it is right firber card, top port (module 8) lines 61 to 64 not equipped
  17. icstech

    12x0 Trunk Module Card 1 not equipped

    phoneguy427 It is plugged into the left 6 port fiber card bottom port and all other ports are being used by stations Yes it is a 7.0xc (to use all fiber ports) On the hardware the 12x0 shows up on port 8 but only card 2 and 3 shows 4 lines each. Card 1 shows 0 lines and unequipped
  18. icstech

    12x0 Trunk Module Card 1 not equipped

    hi phoneguy427 Did that already no luck. Even tried the other setting E&M etc. I only thing I can think of is that there is some limitation when using a T1 card. But the manual says all slots can be used. any other ideas ???
  19. icstech

    12x0 Trunk Module Card 1 not equipped

    I have a modular system with a T1 card in slot 1 and trunk card in slot 2. A 12x0 trunk module is is installed on port 8 (two combo fiber cards). Here is the problem, on the 12x0, card 1 is showing unequipped, I have tried disable and enable the card and module with no luck. The lines in...