You can use it on the external port, but the 221 is a single channel controller. This means you can't use both the inside and outside at the same time.
Look at getting a 3200 so you can use both channels and will not have to lose any date during the upgrade.
Not correct - jeffpenn is correct except he failed to mention that you need to go back into ACU and create new logical drive from the new free space. You can then see it in the OS. This will not give you a larger C: drive without 3rd party spanning tools.
Try making a connection to the remote servers IPC share first. From the cmd prompt, enter
net use \\servername\ipc$ /u:Administrator *
It will ask you for the admin password for the remote machine.
You may need to turn off Discovery Filters. By default we only look for Proliants. If you turn it off, we will find everything on the network. Dell runs DMI, which is a Desktop protocol on their servers, so importing MIBS only helps on some of their equipment, but you may want to check into...
Check to see that the DCE side of your connection has a "clock rate" command int the Serial interface section of the config. YOu can tell which end is DCE by running "Show controllers".
Adding the floating secondary static route is my intention down the line, but adding it now only sets me up for failure later. You see, if I have 2 default static routes and they have the same AD (1 by default) then the router automatically starts load balancing packets. When I do this, I get...
You need a 3rd party tool and you have to add it to the NT scheduler. YOu can find snmp tools at http://www.simplesoft-inc-snmp-network-testing.com/ and many other places on the web.
I understand that a Gartner Group study showed that a company considering a switch in server manufacturer platforms would need to realize a 28% decrease in total cost if they are activley using IM7 today.
Clearing Status and clearing events are 2 different things. Clearing evnts will not change status, it will simply "clear the event". Try creating a query that displays on the screen what you want to accomplish and then create a task based on that query that takes the action you want.
Desktops are not added in the same way as servers in CIm(win32 version). You need to enable Desktop mgmt in the CIm agents on the PDC/BDC and then add aline to the login script that dynamically adds the clients to the console. Insight 7 handles this much better
Oh - I forgot to mention that I had removed the other static route from this config to get it routing back through S0 - the other route was
ip route 0.0.0.0 0.0.0.0 Dialer1
Thanks
I have a 1720 with 1 FastE, 1 Serial, and 1 DSL WIC installed. I want to use the Serial as the primary connection to the internet, and the dsl dialer as the backup. If you have not used DSL before, think of it as ISDN, as it used a dialer in the same manner.
My problem right now is if I...