Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. marty773

    Cross Talk

    We are having an issue with cross talk. We are currently chasing circuits packs in the port networks and have heard that it is possible that the pack causing the issue does not necessarily have to be one on which the offending phones are programmed. We are at the point now where we would like...
  2. marty773

    Ec500 with call coverage

    Looking for a way for an Ec500 station to continue ringing once the call has gone to coverage. This assumes that the call covers to another extension, say a secy, before it goes to VM. Any help is appreciated.
  3. marty773

    Ec500 limit to 4 station mappings

    When I attempt to add the extension to the table and press enter i get an error that says "1400" Maximum number of applications already administered for this extension.
  4. marty773

    Ec500 limit to 4 station mappings

    Thanks for the post but that does not seem to be the case in CM 5. I only have 2 call appearance on the phone yet it allows 4 station mappings. I have tried adding a bunch more and it still only allows 4 entries in the table for one extension.
  5. marty773

    Ec500 limit to 4 station mappings

    We are using CM 5.0 and using the Ec500 feature. Plemty of licenses. We have a help line we would like to ring more than 4 phones. When attempted to map a station more that 4 times the system says the maximum number of applications for this extension has been met. Does anyone have a work...
  6. marty773

    Per Call CPN block

    I have an OLD Definity. G3csiV8. It has straight t-1's in it installed as Tie trunks from Qwest. I need to be able to block outbound caller ID on a call by call basis. I programmed a FAC code of 123 for per call CPN block. On page 2 of the trunk form I programmed *67 (the code noted as...
  7. marty773

    Overlay Conflict Message on Element Manager

    I have the same issue. Here is what i get at >who TTY 00 SCH MTC BUG 9:47 OVL111 MIDN 43 Does this mean the midnight routine is locking me out? If so, how do I stop it? Thank you
  8. marty773

    120A CSU not working on PRI

    Thank you everyone for your help. I was using a board with a bad fuse. Thanks again.
  9. marty773

    120A CSU not working on PRI

    I have 6 120A CSU's I have tried to use on a PRI circuit into a G650 cabinet, CM 4.0. I get a solid red light on the top of the 464 F card and status light 1 blinks red. I am using a straight through cable and have set the CSU type to integrated on the DS1 board. I have swapped 464F cards...
  10. marty773

    Delll 2650 drive problem?

    Have a Dell Poweredge 2650. Was receiving an Amber light on one of the disks indicating a bad drive. I believe it is a RAID 1. The LED on the server had an error EOD76. When I put the replacement drive in it would still flash amber. I rebooted the server and with the new drive in it would...
  11. marty773

    G350

    I verified the default gateways are the same through the command line and the maintenance web page. The keypad tones work, and I can call between the phones but I do not get dialtone when I pick them up. Any other ideas?
  12. marty773

    G350

    I have a G350 with a few phones on it. IP 9630, digital and Analog. I do not get dialtone when I pick any of them up. I can call between them, but nothing when I go offhook. Is the dialtone internal to the gateway? Is there anything to check in software. I know there is no tone clock as in...
  13. marty773

    Powering 9630G IP Phone

    I am trying to use an external power supply on an Avaya 9630G IP phone. I am using a working 1151B1 power supply. When I plug in the phone, the power light just blinks. Am I required to use the 1151C power supply? Any help is appreciated.
  14. marty773

    Mitel sx-200

    We have a Mitel sx-200 with 3 cellular lines as the only trunks to the outside. We get dialtone on the line and press 9 to access the cellular trunk and dial the number. We get dead air. If the number is dialed again, not including the 9 TAC, the call will go through. Why the need to enter...

Part and Inventory Search

Back
Top