Hi Guys,
I have a problem with my lifetime free miniSIPServer V40 for 5 clients :
All my calls are limited to 30s (seconds) and after I have extended all time settings to the maximum limit but nothing changed.
Did anybody tried or used this software ?
Stefan
cristeasta yahoo com
You can contact me directly there if you want to help me find an entire extension shelf equiped with only 3cards, 2 shelf interface for CPU-A and CPU-B and an CEC card, with all the ribbon cables installed on the back of the backplane card, in case I would like to install...
Thanks Buddy for your advice, unfortunately I couldn`t find the Homeworking Siemens DX Manual and I must resume myself to what I can find inside my DX-150E manual, which is not to much and not even to detailed. Regarding what you told me :
?lco 14
ENTRY NO CHARGEABLE OPTION AVAILABLE UTILISED...
Here is what I did, but I`m stuck and don`t know exactly what should I do further to complete the entire task :
lex 2929
SN2929 SPARE
nvn 2929
rper 2929 hw y 0213186120
scs 2929 31
stac 2929 31
lper a
C O...
Unfortunately for me my PBX is older :
Unpublished Work. Copyright Siemens plc.
All rights reserved.
DX ATDBN9006 26978.01 01.030
9.0.061 /01DUK 0001000 UK 14 12/10/05 A M 081
HiPath DX DUAL PROCESSOR
01/07/20 08:22:35
SMI A> se
SER1=9600
SER2=9600
SER3=9600
SER4=9600
REMOTE=4...
Thanks buddy for your advice, but I already did everything you said earlier, beside all these my system is :
Siemens Real;itis HiPath DX-150E Dual procesor with 28 slots on each of the 4 shelves I have inhere.
For the moment I abandoned the search because I couldn`t find any spare parts for the...
Hi Folks,
Maybe this could sound like a crazy challange for most of you, but I still want to post it inhere as a new thread :
I want to try the impossible, to send a PBX analogue extension through an internet connection using 2 VoIP Routers at both ends without an VoIP PBX or an PBX which has...
More than sure you will not find any of these cards on iSDX/L, because as I already told you, I have one inhere on my site and nothing match with the DX-150E which is a Dual Processor type.
Mine is an DX-150E which doesn`t match at all with iSDX. I have an old iSDX/L inhere in standby just in case of spmething, so I already had this experience, believe me.
I need any of the following as spare parts :
P1 Control B backplane 1HBC50072
P1 Control A backplane 1HBC50071
P2...
I already did it but result was the same, soI suspect the backplane card or the shelf bus more than anything else.
Unfortunately for me I dodn`t have direct access to any spare parts supplier, that`s why I resume myself just trying to guess the cause of all these than tofind a real remedy.
Hi Folks,
I have an EXTN card which after I installed it in an Spare slot and activated all ports and installed and activate all channels with all EXTN numbers, I don`t have any dialing tone on any of these EXTN ports. Bellow I will detail everything I did in settings :
lslt 0422 c
0422 SPARE...
Thanks for the tip, I already ordered an MT5600ZDX modem but it will arrive on 6 July. Until then I will try to do something with those which I already have, who knows maybe I will make at least one of them to work.
Thanks but I already did all these settings, my problem now remains that my US Robotics Courier 56K V90 Model: 3453C Business Modem doesn`t do Handshake with PBX modem. I tried with the same initialization string sent from my modem to the PBX modem but unfortunately it doesn`t send anything on...
I succeded to use NSEX, REO commands,but when it came to RRAS command I received an error message : ERROR: NEW RAS LOCATION INCOMPLETE and it seems I missede something very important on my way.
Can you give me a little help here ?
In addition to my first post.
Unpublished Work. Copyright Siemens plc.
All rights reserved.
DX ATDBN9006 26978.01 01.030
9.0.061 /01DUK 0001000 UK 14 12/10/05 A M 111
HiPath DX DUAL PROCESSOR
03/11/20 13:37:05...
Hi Folks,
We are a Romanian Telecom Limited Company based in Bucharest, Romania, who are operating the only PBX Realitis DX150E Dual Processor in Romania.
We had several partners in the past in UK, but most of them are now in pension, or their companies are no longer active on the Market.
In...