My DRS link is stable with far end,all E1 data is stable however there is variation on Ethernet connectivity at same link. Receive level is within limits and stable but Ethernet data is cutting.....
How to resolve the issue ?
Follow these steps to Up the trunks.
1. Go to LD 96
2. Disable associated D-Chaneel ie DIS DCH xyz.
3. Go to LD 60
4. Disable concern loop ie DISL 135
5. Now enable the loop ie ENLL 135.
Nortel digital set 3902 went out of service oftenly, I have 7 unserviceable sets. 03 having display problem.
How to recover them and how to safe them for future ?
Thanks dear Firebird...
i had heared by somebody about insertion of diode in specific configuration near Rossett to safeguard the digital sets but not exactly know how to insert the diodes..
Anybody else to help me ???
I am maintaining Nortel Meridian opt 11c at top of hilly terrain where thunderstorms and Heavy lightening is common phenomena. It is pertinent to mention that my 3 to 4 digital set 3902/3904 had become unserviceable during this type of weather condition. I have installed IDF tag block with...
Thanks KCFLHRC...
I have reset DTR and found tones on Main cabinet slot 3 and 7.
I adopted following procedure.
LD 32
DISC 0
ENLC 0
Now my 2 cards are working smoothly and will move rest of the ALC cards from Expansion cabinet to Main cabinet shortly.
Here are the results (attached) in LD 32.
https://files.engineering.com/getfile.aspx?folder=cf3873dc-d29f-4be8-8d83-6ddf9f5302b3&file=IMG_20201205_100509.jpg
Ok let me guide ....
1. How to take print ? LD and command plz ?
2. How to enable disable DTR ?
3. How to configure new DTR ?
4. What will happen if i disable or OUT DTR ? Is there any effect on digital numbers and analog number in 2nd cabinet ?
Thanks KCFLHRC.....
How to check DTR and how to configure it in the system ???
I have Meridian 11c with no dts/conf card.
having SSC card in slot 0 of main shelf/cabinet
LD 117 displays all type of card configured in any slot including alc,digital, dch and xut.
if we print inventory in LD 117 it shows ALC card configured at slot 7, 8 and 10.
In LD 32 shows idle status of all ports of all cards.
But no tone is available at any port/slot and card.
How to resolve ???
I have configured new ALC cards by generating inventory in LD 117 at slot 7,8 and 10 of main cabinet. Inventory generated, card synchronised and showing idle status in LD 32. But no tone at any port, any card of any slot.
It is confirmed that all configured cards are serviceable.
I have following equipment with power consumption with each.
Router = 370 Watt
Switch = 520 Watt
DSLAM = 70 Watt
Switch = 550 Watt
How much Rating UPS is required to hold these equipment for 1 Hour ?
Yes ALC = Analog line card.
All (04) ALC cards are configured and operational in expansion cabinet. But i want to shift them from expansion to Main Cabinet. I generated inventory in Main cabinet but no tone was found on any port in any slot any card installed in Main Cabinet....
What is solution ?
I am using 11c switch having 02 cabinet but all ALC(04) card are configured in expansion cabinet. No ALC card is being configured in Main cabinet. Inventory generated, no tone found on any slot any card and any port of card.
What is solution ???
I am unable to resolve problem.
please explain command and procedure of backup...https://files.engineering.com/getfile.aspx?folder=ac1faffb-81a4-4d79-ab41-4c02a637ca27&file=IMG_20201123_111422.jpg
I am unable to take backup of Meridian 11c.
Whenever i give command "xbk" in LD 143 , its starts Backing up but never completes. Its stuck in middle point
I have Meridian 11C with CS1K , i am facing issue regarding external incoming calls All external incoming calls are being diverted automatically at only operator Digiti which is ext 15. How to fix the issue so all calls are to be recieved on there own sets ?
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.