  1. Roo Richards

    MATWorx 13 on Windows 11

    abayham, winner winner made the changes in regedit as described and the program loaded and seems to run withoiut issue - after setting it for compatability mode thnaks again, saves me carrying two laptops when I look after 4 x IPS PABXs on a preserved railway telephone system. i havent had to...
  2. Roo Richards

    MATWorx 13 on Windows 11

    so that was definately on WIN11?? I have had it working on WIN10 as well
  3. Roo Richards

    MATWorx 13 on Windows 11

    trying to install MATWorx v13 on Windows 11 and getting the following error message. seemed to work fine on WIN10. cant run it as administrator as it hasn't loaded yet, tried a few different compatibility options but still get the same error message "failed to get application Information value"
  4. Roo Richards

    NEC CP24 Backup battery

    looking to replace the back up batery on a CP24 IVS(IPS) PABX CPU card due to the welding of the tab on the battery i can tell the model number current voltage on the existing cell is 0v! any ideas on the battery model?? im guessing this is the cause of the time clock changing erratically
  5. Roo Richards

    outbound CLI when SV9300 is tandem switching to ISDN trunk

    when i make a call from an extension running off the SV9300 - which has the ISDN connected - outbound CLI works its when i am making a call from the remote IVS2 via IP trunks on CCIS to the SV9300 which is tandem switching the call out through its ISDN port that i dont get the outbound CLI. the...
  6. Roo Richards

    SV9300 IP Station logout

    never realised you had to be off hook to effect log out. Ill try that when im next back on site this weekend - thanks dont remember that being the process when i was first playing with IP stations on an IPX240 years ago. I had one IP station at work and another one at home on a VPN. great for...
  7. Roo Richards

    SV9300 IP Station logout

    i have a I series handset connected to a SV9300 and dont seem to be able to get the log out button to work i have CM15-143 set to allow for IP station logout for service restriction 15 (default the extn is in that service restriction class. the function key F0B39 is set on key 7 (F0#39 when...
  8. Roo Richards

    outbound CLI when SV9300 is tandem switching to ISDN trunk

    System A is a IVS2 (IPS) with IP trunk tie line to System B which is a SV9300 with Rt 11 being a carrier ISDN trunk. LCR routes and outbound call from System A across the tie line to System B which then routes the call to the carrier ISDN. The extn in system A is within the indial DID range of...
  9. Roo Richards

    SV9300 to SPA122 will not register

    NEAX, it is on a SV9300, and last night i added another STD SIP acct but it didnt appear to need a RESET I have also successfully connected to both the SIP accounts using XLIte andmade inbiund and outbound calls, so from that I presume the 9300 is set up correctly. It is now trying to work our...
  10. Roo Richards

    SV9300 to SPA122 will not register

    hmmm, still not getting anywhere is there some command under CMD 08 that i should have considered also CMD1290 gives an data error if I try to look up the MAC address - I thought I might be able to enter it manually and make the system register via MAC address,
  11. Roo Richards

    SV9300 to SPA122 will not register

    copied and modified from another thread, we have programmed the PABX as follows Programming example CM 1001>0043>EEC000 Assign the SIP converter number to the Virtual Port number for SIP station CM 1004>000>764 Assign the SIP station number CM 1D14>764>0 Set the SIP station to PHS CM...
  12. Roo Richards

    ivs2 (ics120) Outbound CLI

    Billz66 thanks, it was 1213 that was the clincher it was set at default 15 Roo
  13. Roo Richards

    ivs2 (ics120) Outbound CLI

    trying to get outbound calls to present extn level CLI/CND on an ISDN trunk. already working for other extensions ISUBN is set to x725 and CLIR is 1 - same for the extension that is sending CLI/CND am I missing something? checked through cmd 12 & 13 and cant see anything else
  14. Roo Richards

    NEC Univerge NEAX IPS DM - set phone to ring

    I just learnt something, always had to go to CMD> 9001 to do that!
  15. Roo Richards

    call forward on linked PABXs

    Belvedere you are correct it is a bit of circular activity but hopefully not for long. You were right on the money, it was a 360>3030 limitation, opened it up and it all worked Thank you
  16. Roo Richards

    call forward on linked PABXs

    in the middle of a migration in Australia, moving a network of 6 PABXs from ICS120 to IPS. the only one left as a 120, is the main site (switch A) make a coffee, settle down, this isnt going to be a quick one I suspect. see the diagram below to get your bearings main PABX is ICS7400/120...