the ranges did not exactly all show up. when i added 6601, it added the range of 01-10 i had to add each 10's range in order to get them to start showing up.
but the did! thank you for all your help.
OH!!!!!!
ok. so when i added 6601, it actually let me. and then the range of 6601-6609 showed up in the ludn. So basically i just had to add a number in each of the 10's block of the 6600 series, and it opened them all up.
Thank you everyone!
When i outed this, it gave me 66 in the LUDN, but not the rest of the range.
i did locate this
DSC 66
FLEN 0
DSP LSC
RLI 12
Which is pointing the DSC of 66 to RLI 12 which is an old Sip Tie trunk that we no longer use. So now it looks like i need to remove this trunk, but i want to be...
Starting a new thread as previous thread lead me to a new list of questions.
I have a CDP, 66 This used to be a tie to another pbx, but is no longer.
I need to open the entire range of 6600 - 6699 for use as DN's. (we purchased this whole block as DID's)
Could use some assistance in...
ok, so looking at this, i see that 66 is being used as a coordinated dialing plan. I do not have any additional PBX's tied into this switch however there may have been one in the past under previous company ownership.
Is it possible to Out a CDP, and if i do so, will that make the range...
We recently purchased a range of DID's 6600-6699
When i do a LUDN, the 66, and 6600-6699 extensions are not listed.
What do i do in order to A. Find why this range is not available, and B. Make this range available?
turns out a late night graceful power cycling of phone system brought all systems back online. was hoping for a command line to restart signalling server however was not able to find one in time and had to restart.
So this is what i get as a result.
I'm not certain if i'm reading it correctly but with the state of Link Up, i would think it should be good.
How would i go about restarting the signalling sever? do i just need to power cycle the pbx cabinet?
NODE ELANIP LDR SRV...
Hi all, hope you can help as i'm a bit stumped. We were doing some network reconfiguration about 2 weeks ago, and ever since the networking was done (unfortunately i can't go back) the phones are able to make and receive calls, however they are not able to use any of the advanced phone...
Mikepbxb, Thank you very much. your trick regarding leaving the customer blank was just the ticket.
The card has been moved. I'm adding my output below for future admin's having similar problems.
REQ mov
CUST
SRCL 8
DSTL 8
SHCD 0 7 to 0 2
SHCD
FORCED DISCONNECT SOURCE
FORCED...
So i've been doing a bit more investigation into this which might help shed light on my problem.
the cabinets i'm working with are part of a Media Gateway Controller that is separate from my primary PBX which i am logging into.
I can login to the secondary media gateway controller as Admin...
This is what i get when i try to mov via ld 25
REQ mov
CUST 0
SRCL 8
SCH5235
The cabinet does show 8 on the card.
*edit. specified that i tried to mov via ld 25
I am trying to move an Analog Card. I'm having some difficulty with this. I believe it may have to do with the fact that this system is on a different loop. It's listed as loop 8, but when i list the loops in my switch i do not have 8.
I've recently inherited a Nortel CS1000. It's been a few years since i worked on one and i'm a bit rusty. hoping someone can point me in the right direction.
I have 2 separate cs1000 stacks. One of them has been out of service for awhile. I have a new building that is being built, and i...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.