Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. VonZipper27

    mitel sx200 911 issue

    So, release 2 doesn't do it?
  2. VonZipper27

    mitel sx200 911 issue

    So, is there any way to make them show on the console
  3. VonZipper27

    mitel sx200 911 issue

    Software lw17 2.00.19, from reading on the web, I need to set 911 and 9911 as emergency, but I cannot find it. I am trying to get 911 calls to show on the console.
  4. VonZipper27

    2000icp and echo on IP phones

    Changed loop to short, and imp to 600ohm...no more echo. Thank you!
  5. VonZipper27

    2000icp and echo on IP phones

    Right now the trunks are set to auto under impedence. The echo is my own voice coming back to me within milliseconds. so basically hearing myself talk right after I speak. I will change them to 600ohm?
  6. VonZipper27

    2000icp and echo on IP phones

    I just installed the above system last night. This morning, the customer is telling me there is echo, and I have confirmed. On all IP phones, I hear myself back clear as day. How do I get rid of this? They have 4 analog trunks. The single line phones seem to work fine.
  7. VonZipper27

    My first Mitel sx-200 ax ICP

    The new java is stupid, have to add addresses for it to work...not a fan lol.
  8. VonZipper27

    My first Mitel sx-200 ax ICP

    I cannot remotely get into the system, sorry. I set the router to forward port 80 to my system for the web browser...I can log in, but it wont connect to the cde forms. I will have to update you all when I get onsite.
  9. VonZipper27

    My first Mitel sx-200 ax ICP

    I will have to get back to you monday.
  10. VonZipper27

    My first Mitel sx-200 ax ICP

    I have a 24 port system. If I call the phone and its busy, i go right to the vm box, if I call the phone and its idle, it rings the phone three times, then goes to the attendant, literally answers and says its transferring me to the attentant.
  11. VonZipper27

    My first Mitel sx-200 ax ICP

    Yes, they are both set to 300. I thought it might bebecause the box wasnt setup, but that was not it.
  12. VonZipper27

    My first Mitel sx-200 ax ICP

    They are loop start trunks. The phone i am test8ng with is a office phone, and its mailbox type is extension. I have a co line key appearence on the phone, so a loop start trunk is assigned to each office phone. When i call the phone and its idle, the vm answers saying it is sending me to the...
  13. VonZipper27

    My first Mitel sx-200 ax ICP

    when I call one numbers assigned to one of my IP phones, in cos 1, it rings three times, then tells me I am being transferred to the operator. Any idea why?
  14. VonZipper27

    My first Mitel sx-200 ax ICP

    its not going to be good
  15. VonZipper27

    My first Mitel sx-200 ax ICP

    i am all ready up to 295... What a pain. I even tried doing a range program to change the cos on the exts, no help...Oh well...I think it may make it in tomorrow morning...I have a guy there putting in all the cables and cleaning up the room. Somehow he killed their console on their old NEC, so...
  16. VonZipper27

    My first Mitel sx-200 ax ICP

    I did not set option 277 in the class of service for all my guest rooms. Is there an easier way to create all those mailboxes rather than one at a time?
  17. VonZipper27

    My first Mitel sx-200 ax ICP

    oh my...trying to set this guy up to allow outgoing calls is a chore! It appears to be working though.
  18. VonZipper27

    My first Mitel sx-200 ax ICP

    amb combo class is the ticket
  19. VonZipper27

    My first Mitel sx-200 ax ICP

    nope, that dont work, says the tcd must match the circuit type...
  20. VonZipper27

    My first Mitel sx-200 ax ICP

    I have three 4+12 port combo cards. I am going to have 11 loop start lines. I see how to route them in form 14, but I have to add them to a trunk descriptor in form 13. None of them make any sense to me, but, I am assuming I choose the 4 circuit class? Do I need to change anything in the options...

Part and Inventory Search

Back
Top