Dear guys
can somebondy give me the part number for the integrated power supply from a WS5A. And is this power supply compatible with the TM-T88 printers?
I'm also wondering we use her in Europe "Umlaute" like ä,ö,ü but I cant print some receipts with this atm. is there an option how I can fix...
Hi pmegan,
everything works fine after the update :) If you are interessted in WS5A for your business let me know I can give you some address or maybee some people from this forum sell some "used" WS5A systems. If you buy them new they cost 2'600 USD or more and the used ones with new displays...
Dear Guys,
I was looking for a VNC build for our new WS5A. And I found this VNC configuration how works very well with our new systems.
Download Link
Copy the folders in to the ..\MICROS\Res\CAL\WS5A\Packages directory
After the CAL Configuration you can access your workstations over the...
Dear DJense999,
thanks for your help and also the files. I could make the update on the MICROS Server and will test tomorrow if it works but it should work now.
For VNC I just made a copy from the WS5 directory because in all call folders are the same files I hope this works as well for the...
Thanks for the update we are atm on version 4.7.1.2284 did we need some other updates befor we can run the patch?
First of all I Shut down the MICROS Server and afterwards I run the Patch.
Is this all what we have to do for the update?
And I got some Error with one unit if Windows CE gets...
OK on our Server there is no WS5A directory under D:\MICROS\Res\CAL can I copy just the WS5A directory from one to the other server? Or did I need future assistent :)
Kind regards
Simon
Ok I'm done with the System and I also have chosen the same configuration as on the WS5 systems.
But on the Screen with the Workstations there is no Option to Select a Produkt? And the CF directory is empty.
Any suggestions?
Kind regards
Simon
Hi diaczykmd,
you should open the POS Configurator / Devices / Devices and set a new device.
Under General select Device Type: Roll Printer / Network Node: MICROS Server (is up to you)
Go to Printer Definition: Printer Interface Type: TCP/IP Interface / Printer Type: Epson TM-200 Roll
Go to...
But I have 4 workstations WS5 already up and running this ones should show up in the list. I also already changed the network node type from workstation to workstation4.
Any other Ideas I think is tricky that the server shows up but not one of the workstations.
Kind regards
Simon
Ok the new WS5A Stations are here and I can start the MICROS CAL client als also I can see our Server BUT on the next Screen how the availaible workstations are listed I can't see any availaible workstation.
Are there any tipps for this scenario?
Gruess Simon
Dear OutDoorType,
Windows 7 and MICROS Call client work just with a MICROS POS Version 5 or higher. You got an error message if you try to install the MICROS Call client on a Windows 7 system.
One option is to upgrade the Server to Version 5.X and then update the client but I'm quit not sure...
Dear Users,
we getting 3 WS5A workstations is there any need for a firmware upgrade? We are using on our Server MICROS RES 4.8
MICROS CAL is anyway already preinstalled also Windows CE and I never updated one of our WS5A stations :) because of the reason "don't touch a running system" they...
Sounds good because the quote from MICROS Europe was we have to buy two new Licences for arround 2'000 USD for two WS5A Clients and 2'400 USD for the installation / replacement I was thing this guys are joking me. I payed already for the CAL licences and we also don't need a new configuration...
Hi Wildbar,
thanks for the informations I was thinking that we don't need a new licence. We ware on Res. 4 Version 4.8 Build 4.8.4.2841
Here in Europa the MICROS Support tells us we should not upgrade to Version 5 they have a lot of problems especial with Fidelio and MICROS.
Only Reason to...
Hi all,
I'm wondering if we can replace two old POS Stations with Win32 Call Client for MICROS POS 3700 with two new WS5A Stations.
Did we need new Licence Keys from MICROS? Or can we just Replace the old stations with the new onces and start the windows call client?
Did we need some other...
Thanks pmegan for your help.
I found the problem it was a simply DIP Switch Setting.
For the TM-T88IV System and MICROS POS 3700 I changed the settings.
DIP Switch 1: 7 ON / all other OFF
DIP Switch 2: 2 and 8 ON and the other OFF
Works like a charm with the settings in my first post. I aldo...
Hi Community,
I spend over 3 hours of my time to get this printer working. Maybe one of you have a idea how the problem could be.
Hardware:
Epson TM-T88IV with Ethernet Interface
IP: 192.168.10.70
Subnet: 255.255.255.0
Gateway IP: 192.168.10.1
I added in MICROS RES 3700 unter Device this...