So the PGd say it can handle both door box and external paging using o e extendion port dlc
I was able to get external paging working (using first port on dlc blade to Pgd now I need a door box I have jumper set correctly and wires on unit in right place for both but cannot get door box to work...
User are complaining that Voicemails volume going in/out. Was able to duplicate by calling DID leaving VM and message volume went in and out completely. Calls route into 9500 over IP CCIS to 9300 then back to VM where 9500 is located
my routes are 10, 12 , 14
Is this aPad issue if so what are...
On Tuesday desiless phones on 9100 if you have a key ring on second page say a cap key or virtual does it take priority when right gingnor donyou have to scroll when ringing to second page
I habe set up extensions in 46 command and created access code but TDM phomes not receiving all call page. Os there a command to turn on so that other will be proovded to each extension ?
I have 3 phones onsite that when dial out there is a delay from when their voice is heard from distant end. TDM phones. I have 100 other phones onsite that are not experiemcing this problem. Everyone dials out the same PRI , they are in same class of service. After about 5-10 seconds their...
Is there anyway to turn off the light on side car only when user programms one touch button to call another extension. They do not want itnto light up when other user is on their phone
problem getting IP6000 polycom to register
All my ip phones work fine
I have 5 stanard sip station licences
My network 192.168.10.20 for SiP several
Sub 255.255.255.0
Gateway 192.168.10.1
Port 5070
UDP only
Dhcp is off on unit
Extension 3898
Login 3898
Static address
1004 set std sip...
Thank you for response
08>140 = 0
1303 Xxx is set to 0 which is NOT def. 0= To provide (Fornstation with meassage lamp )
Still no light
In found where to make it flash or solid once it works. In 08>294
Have a customer need sublines or Virtuals for Departments to flash when there is a voicemail in the box to show on line key
I found 08> 713 > 0
08> 140> 0
still missing something ,, not lighting with message in box
Hi can i download latest version software from NTAC and jump to patest from an old 2.02 . what is the best way to perform this upgrade via PCpro or Stick
AD-8 was replaced IM-16LX on an old 2000. Auto logon works but Message waiting indication not lighting lamps . curious if it the Integrstion string or MWI field ... What should it be set to?
Inmail 9100 I have a custoner with access to PC PRO so they think they can program . someowhere in their creative arts they somehow disabled the logoon feature to access your own mailbox from #and extension number . # on all dial action tables is set to Logon #IXXX and all exts are 3 digit . in...
Getting back to original l thread I. Going back Monday to site I have a compact flash reader and latest version of NEC CF tool . Csto er has given us a couple hours to shut down system. I need to Take CF in CPU 0 and copy data to CF in CPU 1
If anyone has step by step instructions I would...