  1. jarruda

    External Calls going to the Attendant Console

    Hi sbcsu, I did tried with intercept feature deleted from FEASU and checked that the tested extensions do not had DND enable but event then it keep doing the attendant intercept. Very weird... any other clue?
  2. jarruda

    External Calls going to the Attendant Console

    Hi sbcsu, The trunk have COT 6 for sure, I triple checked it. It could be something else in the Hipath setup as you mentioned since the described Hack above worked as a workaround. I did get traces on the SIP side, there is no signaling being done when the call is intercepted by the attendant...
  3. jarruda

    External Calls going to the Attendant Console

    sbcsu, Thanks for your reply. In fact before posting here I was following the documentation breadcrumb trail and I saw those COT parameters. As you can see bellow, in the COT being used by this trunk (COT 6) none of the "Intercept...." (IIDL,INDG,IONS,ITB,IVAC,IBSY) parameters are enabled...
  4. jarruda

    External Calls going to the Attendant Console

    Found another clue. Looking at the AMO VFGR i found that my Attendant Console Group have the following config: | IS INTERCEPT DESTINATION FOR THE FOLLOWING ITR GROUPS | | 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 | As its impossible to...
  5. jarruda

    External Calls going to the Attendant Console

    Hi, sorry I forgot to mention, this is on a Hipath 4000 system. There is no call forwarding (unconditional, busy or not answered) at all configured on this extension so it might be something else that is getting the external call on both cases and sending them to the Attendant Console.
  6. jarruda

    External Calls going to the Attendant Console

    Hi folks, I have two scenarios (that seems to be related) that I want to change but not sure how to. Case 1: An external call is received by a Trunk Circuit (E1-R2) with a busy analog extension as destination. The analog extensions hear the call waiting tone for some seconds and after a period...
  7. jarruda

    Timer for E1-R2 (Brazil) channel (Dev type DIUCQ421) get response for outside call

    Just for reference, I was able to resolve the issue. It turns out that I was reaching two 15 seconds timer. 1) The first one was in the Cisco GW (that's why trying many changes in Hipath side didn't fix the issue). The configuration to be changed was alert-wait-time (Time to wait for alert...
  8. jarruda

    Timer for E1-R2 (Brazil) channel (Dev type DIUCQ421) get response for outside call

    sbcsu, Here is the result for Comwin/Macro/Retreive System Variant: <HicomLanguage=English DISPLAY-VEGAS:LIST=SHORT,UNIT=SWU&ADS; DISPLAY-VEGAS:LIST=SHORT,UNIT=SWU&ADS; H500: AMO VEGAS STARTED SYSTEM NO. AMO APS NO. START USER STATUS SWU...
  9. jarruda

    Timer for E1-R2 (Brazil) channel (Dev type DIUCQ421) get response for outside call

    sbcsu, Do you have any instructions on how do get those "Hard Disk traces"? I need to check if I have any Assistant working at all and I didn't know that there is another way to trace calls. I did a full debug on the Cisco GW to check this.. and it seems that the disconnect signal is really...
  10. jarruda

    Timer for E1-R2 (Brazil) channel (Dev type DIUCQ421) get response for outside call

    sbcsu, The only way to do the trace is using the Assistant right? Do you think the trace would tell which timer to look for? I saw the doc you sent, it do not cover much of this kind of E1 signalling issue. Regards, Joao Arruda
  11. jarruda

    Timer for E1-R2 (Brazil) channel (Dev type DIUCQ421) get response for outside call

    Hi folks, I'm trying to found a way to resolve the following issue: In a setup with this configuration: -------- ---------- ---------- ---------- | HIPATH | -> | Cisco GW | -> | Cisco GW | -> | Provider | -------- E1 -------- SIP ---------- E1 ---------- When...
  12. jarruda

    Difference between (COS1 and COS2) and (LCOSV1 and LCOSV2)

    sbcsu, Thanks you very much for sharing your knowledge it's very appreciated.
  13. jarruda

    Difference between (COS1 and COS2) and (LCOSV1 and LCOSV2)

    Hi folks, Sorry that this one can be really basic, but I can find the answer for it in the Siemens doc I have. Can someone explain what is the difference between (COS1 and COS2) and (LCOSV1 and LCOSV2) in a station configuration? If I have the following config, when the different settings...
  14. jarruda

    LCR digit pattern maximum digits in length

    sbcsu, Thanks for your quick reply. I see that using LODR to outpulse the **1234567 would work somehow. The problem is that I have more than 1600 valid PIN numbers, so I can't see a way to make it work for all those numbers. I'm interested in the latest suggestion "Another way would be to...
  15. jarruda

    LCR digit pattern maximum digits in length

    Hi there, I´m doing an integration of my Siemens Hipath 4000 with a VoIP system. Right now all the E1 connections I have on the Siemens system are connected to the VoIP system using an E1 <-> SIP gateway. While doing this configuration one of the things we look for is to leave the PIN dialing...
  16. jarruda

    MWI Announce in Analog Extensions

    At or Hipath 4000, when an analog extension is flagged with MWI ON, every time the user goes off hook he hears: "A message is available" (in Portuguese). I´m wondering if anyone knows where did this MWI announcement came from and if we can change the recording somehow? Thanks,
  17. jarruda

    Hipath 4000 to Freeswitch VoiceMail using E1 R2 Gateway

    sbcsu, I have not idea how to generate this "message". In my setup I have a voice gateway between Hipath and Freeswitch (E1 <-> VoIP) and can just place voice calls on it. The E1 is R2-MFC signaling, it isn´t ISDN QSIG where I can exchange messages. Any ideas? I´m thinking that maybe I will...
  18. jarruda

    Hipath 4000 to Freeswitch VoiceMail using E1 R2 Gateway

    I added the TSCS parameter in the COT but if I dial 7444+ExtensionNumber (to set the lamp on) from Freeswitch this call is redirected to the Hipath using the VoIP Gateway but is rejected. I´m using an E1 R2 (no ISDN) in this connection. Using a 4000 analog extension i´m able to turn lamp on/off...
  19. jarruda

    Hipath 4000 to Freeswitch VoiceMail using E1 R2 Gateway

    sbcsu, Thanks for the reply. In fact I was wrong. I need to transfer the call to free switch keeping the A party number but forwarding to B number but in the Freeswitch system. I´m able to do that using a code then striping the code prior to reach the Freeswitch. In the other hand, need an...
  20. jarruda

    Hipath 4000 to Freeswitch VoiceMail using E1 R2 Gateway

    Hi there, I´m trying to setup my Hipath 4000 to user Freeswitch as Voicemail server. To reach the Freeswitch I have a VoIP Gateway connected to the Hipath using an E1 (R2 Signaling) channel. I´m able to reach the VoiceMail pilot number (36999) (or any other VoIP extension) from any Siemens...