Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. DanailDS

    tlu25&tlu27 in TSW BC13 SP8

    Dear Colleagues, Could you please, advise us regarding an upgrade from BC12 SP3 to TSW BC13 SP8: Can boards TLU 25 and TLU 27 be used in TSW BC13 SP8 (&do they need firmware upgrade). -If they cannot be used, which boards replace them. We have checked Mittel/Aasra documentation, but for us...
  2. DanailDS

    Replacing LSU

    Thanks a lot :)
  3. DanailDS

    Replacing LSU

    Hi, We need to replace faulty LSU card on BC 12. Can we use the following procedure: 1.bldbi:bpos=x.x.x; 2-remove fail card from mag and insert new card there 3-bldbe:bpos=x.x.x,allfm=yes; No test system BC12 at the moment. Please Help. Thank you! Danail
  4. DanailDS

    MD 110 BC 6 lim dial in/out problem

    Dear Colleagues, at customer site we have an old 3 lim system MD110 BC 6. All phones in Lim 2 cannot dial out. Also they cannot be dialed from outside. They can only dial phones is the system. Here is the alarm log allop; ALARM LOG IDENTITY: CULTURE-PALACE VERSION: ASB50104/10-R2/6/1/C...
  5. DanailDS

    Problem with initial load

    Thank you whosrdaddy! Thank you snor! Thank you inlsp8! The trick with pulling the LPU/LSU during FTP transfer was very very helpfull Thank you, Danail
  6. DanailDS

    Problem with initial load

    Hello, We try to format, but we get the following: niux > atfmt 0 Formatting sector 0 - 7a800 0% done 5% done 10% done 15% done 20% done 25% done 30% done 35% done 40% done 45% done 50% done 55% done 60% done 65% done 70% done 75% done 80% done 85% done stop formating and LPU display 4122, The...
  7. DanailDS

    Problem with initial load

    Hello Colleagues, we need some help regarding initial load procedure We have a test system MD110 BC12, SP7 with NIU2. During initial load when starting loading lim disposition table we got error message “Already assigned”(on the first row CNLDI) and could not continue with the lim disposition...

Part and Inventory Search

Back
Top