Hi all,we just set up new Pri.We can call long distant but not local,we dial 10 digits here for local calls in las vegas,702-XXX-XXXX telco says first digit drops (7) when i call out.7.1 sw rec digits are 4 dial plan set to 10.any help would be great.Thanks
Hi all,new to ip office,have a Luads door ipo500v2 ess.doorphone only rings recpt after the fourth ring.any suggestions on how to make it ring when button is pushed?
Thanks
Hi all,Just had new area code in las vegas 725.Before we only dialed 7 digits now we dial 10.got one custer that can dial any area code but 1-800 any suggestions where I would look to correct this problem.I am sure it is something I did when I changed from public 7 to 10.I may have looked at...
on 5-3-2014 las vegas had a new area code installed,now we must dial 1-702- or 702 in front of other 7 digits.customers with mics 5.1 thru 7.1 software can't call out .they use to just dial intercom 9,seven digits.whats a quick fix on pri programming to fix
thannks all.
I am very sorry if I hurt anyones feeling,not trying to be a smart a**.what happen was telco had decided to change the ckt,and when they completed it and it worked i was just so excited that i gave the wrong response.I do appreciate your help and kindess.I over looked your question the 2nd time...
Who cares about SP it had nothing to do with trouble or fix?Just called customer no alarms or no system reboots today.30 people in office making and receiving calls no trouble.thanks again!
FYI,just wanted to say THANKS for everyone's help.Telco switched from one slot in switch to another,everything came up roses.We can now call to far end and press off on any digits and all calls complete t-1 stays up and system does not reboot,trouble was at Telco.THANKS again for evryones...
yes,6.1 nvram is rel 2,all lights start to flash and system goes down.t-1 goes down then reboots and then ok,until you dial out then as soon as far end ccr comes on then you press off on any digits it drops.please help.thanks
we have changed every part 6 port cb card,power unit, software cartridge,ethernet cord,t1 card,reprogramed whole system.everything works fine you can make long distance calls or local.its just when the far end ask you to put in a ext# or press 0 the system reboots.anyone ever see anything like...
Hi all,can anyone tell me how to fix an alarm code 44,I know what it is ,I don't care what causes it.I just want to fix it,have a pri 5.0 6 port combo.when you call out and try to press off on far end ccr tree t-1 drops the whole system and reboots.mics,just started been working fine for 3...