Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. BigSteve1968

    Mitel SX2000 Hard Drive Max Capacity

    It's ok guys, i've sorted it - didn't read the jumper setting table correctly on the replacement drives! Doh!! Can't believe I made such a fundamental mistake... BTW - our test SX2000 (LW 34.xxx) only has a 4.5GB drive! It is the original one as supplied from Mitel. I presume the larger drives...
  2. BigSteve1968

    Mitel SX2000 Hard Drive Max Capacity

    OK, ignore my last, didn't realise that there was 2 places in the boot process that showed ADRS! Still need to know maximum size of drive though. Thanks
  3. BigSteve1968

    Mitel SX2000 Hard Drive Max Capacity

    Hello all. I'm not after info how to rebuild the HDD, etc as I already know how. The information I am after is, what is the MAXIMUM size of Hard Drive that the system will CORRECTLY recognise? I recently had to buy a 16GB 50 pin drive as that is all I could get at the time but the system saw it...
  4. BigSteve1968

    1608-I Backlight flashing and no info displayed

    Of course - if in warranty! I'm doing a 1616L at the moment. There seems to be 2 different manufacturers FLASH IC's used, one of them takes about 45 minutes to program on our (old) ELNEC programmer. I think it's time to put our hands in our wallet and buy a faster DATAMAN programmer - looks...
  5. BigSteve1968

    1608-I Backlight flashing and no info displayed

    Copy the FLASH IC from a good one. Edit the MAC Address so the correct one is programmed into the bad chip (try FLASH address 000270080h). Reprogram the faulty FLASH IC. Connect to system and double-check MAC address is correct. We've had LOTS of failing 1608L and 1616L phones, either flashing...
  6. BigSteve1968

    Realitis Mail

    I started a thread about this card in December. I've now got the cable / V24 box and filter. Do I just connect via HyperTerminal and if so what baud / parity / stop bits / flow control, etc? Also, do I need special software or is there a setup menu in HyperTerminal (or whatever software) when...
  7. BigSteve1968

    LDK-100 Failed Upgrade - Help!

    Hello all, tried to upgrade our LDK-100, software was downloaded OK but the prompt box that comes up at the end telling you about reset was corrupt. Waited 30 minutes to see if the unit would come back up but it didn't. The 8 LED's are 'running' up and down continuosly in a strange pattern - 1...
  8. BigSteve1968

    8700MS - IBM Server?

    OK guys, i sussed it - it is because I had forgotten to put the DAj1 card back into the PCI slot. I took the cards out as it had a few problems - traced to a fault within the processor (swapped and is now OK). It would occasionaly start boot (BIOS OK, showed RAM / HDD / etc info screen) and...
  9. BigSteve1968

    8700MS - IBM Server?

    Hello all. I'm trying to install CM4.0 on an 8700MS. When i telnet into the system and start the install it asks for server type with several options (Dell / IBM / etc), which should I select? Thanks
  10. BigSteve1968

    ArgentBranch Software

    Many thanks all. Yes, couple of you are correct, the V2.1 is for IP Office, it is the Alchemy V2.2 that I require. Hairlesssupportmonkey, trying to download of rapidshare but it says too many users, i'll try early hours GMT, should be quieter, thanks again.
  11. BigSteve1968

    ArgentBranch Software

    We are a repair company with links to siemens and others but not Avaya, although we repair pretty much any system including Samsung, Telrad, Nortel, Mitel, etc...
  12. BigSteve1968

    ArgentBranch Software

    Hello all, does anyone have a copy of V2.2 software they could send me please? Thanks.
  13. BigSteve1968

    Realitis Mail - How to setup?

    I have been given a realitis Mail Interface (1HAC 50089) to install in our system. We have an ISDX-S. I have added / deleted / moved extensions, added trunk cards, etc so know a little bit about the system but admit i'm no expert! I would appreciate any help to setup, test and put the card...
  14. BigSteve1968

    GDK-100 and a LDK-300 SLIB2E card

    I had a feeling this was the case but thanks for confirming it. Cheers, Steve
  15. BigSteve1968

    GDK-100 and a LDK-300 SLIB2E card

    Moving on from my last post regarding these cards and the LDK-100, would they work in the GDK-100 or is this a bit too ancient a system? Thanks
  16. BigSteve1968

    LDK-300 SLIB2E

    doktor, you is 'da man'! Many, many thanks. We are dealers for Siemens, Samsung, AVAYA, Inter-tel, Telrad and others, but like a lot of repair centres, we will put our hand to anything that will earn us a wage! Mucho Respecto! BIG Steve!
  17. BigSteve1968

    LDK-300 SLIB2E

    Thanks for the reply. Both cards are supposed to have one faulty port but both of them appear not to come 'on-line', the LED is constantly on. Does the system need to be told it is SLIB2E instead of SLIB? Thanks
  18. BigSteve1968

    LDK-300 SLIB2E

    Guys, we rarely get any LG stuff for repair, what we get is LDK-100. We have just received 2x LDK-300 SLIB2E and neither seem to work in the LDK-100 test system. My question is - should they? Or are they designed solely for the LDK-300? Many thanks.
  19. BigSteve1968

    BCM50 Won't Boot up

    No we don't have Nortel Hardware Advanced Replacement support, we are a company that repairs all makes of systems, for installation / maintenance company's. We do have some support from these companies but quite limited, we mostly manage to 'work out' what to do as we have plenty of experienced...
  20. BigSteve1968

    BCM50 Won't Boot up

    Thanks again guys; curlycord, already seen that thread and several similar, the led's act exactly as follows:- power up - both led's are solid yellow for about 10 seconds, then status led goes solid red, nothing else happens after this, any connected phones appear dead from power-up. unit...

Part and Inventory Search

Back
Top