  1. quikster2004

    mitel 200icp 4.0.0.17

    I have the sring ahead and fall back dates disabled in system features. The site is also having the same issue where it will nt take a date or time change.
  2. quikster2004

    mitel 200icp 4.0.0.17

    I have checked the logs and there is no reset happening. On may 4th I was able to change the date to 04-05-10. Yesterday it showed 05-05-05 and the time showed 11:11pm at 9am yesterday morning. Also one time I attempted to change the date, it was 9:12 am after hitting enter the time went to...
  3. quikster2004

    How Do I change dial 0 to go to another extension?

    You could create a vdn with the extension number of 0 that then goes to a vector that rings 100
  4. quikster2004

    mitel 200icp 4.0.0.17

    I have a mitel 200icp that will not update the time and date correctly. I did get it to take a date and time chage once but 2 days later it reverted back. Any ideas?
  5. quikster2004

    viking announcer on definity

    G3si v 6 with guestworks
  6. quikster2004

    viking announcer on definity

    Is there a way to connect a viking announcer for wakeup calls to a definity? The site does not have an announcement board or speech synthesizer. They really want to use a viking. Is this possible? If so what kind of ports on the pbx are needed?
  7. quikster2004

    TN754 Errors?

    If none of the above works, shut down you system and then reseat the digital line card. Then bring pbx back up.
  8. quikster2004

    lights wont turn off

    I have a definity g3v6 that the lights will light but they will not turn off, I can remove the light by using the clear amw all command, but that is the only way. They have an Innline 2020 vm and the codes are being sent but the switch is not turning them off. Any suggestions?
  9. quikster2004

    audix voice mail

    This is a standalone inuity/audix seperate from the definity, with a pi link.
  10. quikster2004

    audix voice mail

    I dont think I can run an audit command, where is that done from? This is an older Intuity/audix box.
  11. quikster2004

    audix voice mail

    Yeah I have got them all removed but this seems to keep happening.
  12. quikster2004

    audix voice mail

    Ok, yeah the second page on all the phones are set to audix. This is a hotel, now today I had an issue where all the message lights were on in the hotel.
  13. quikster2004

    audix voice mail

    I have an audix vm where there is one station that the light will not light. I have made sure the phone is set to led on the phone and in the pbx. I have changed ports in the pbx (G3v6), I have rebooted the vm, I have rebooted the pbx. All setting are the same as other stations that are not...
  14. quikster2004

    No board

    I removed all programming of the trunk group, also removed ds1 and sync source. I also then readded sync source and ds1. What I have found is if sync source is enabled then this will go down in a matter of 3 or 4 hours. If I disable sync so it always times of 01a16 then it stayed up for about...
  15. quikster2004

    No board

    Ok, so i set the sync source to my board slot, 01a16, but the integrated csu would not work no matter what I did. It seems I am getting errors and slips form the visual uptime csu, so then the avaya sets the sync source to the tone/bd. I have set it at 01a16 and disabled the syn. Im hoping...
  16. quikster2004

    No board

    still show tone-bd o1a
  17. quikster2004

    No board

    when i stat sync it states 01a tone bd, i want it to go to my ds1 bd, it is programmed as primary but still shows as tone -bd- help please
  18. quikster2004

    No board

    Currently there is a visual uptime csu. I am replacing it with a avaya 120a2 integrated csu. This should be sufficient right?
  19. quikster2004

    No board

    This is no longer stating no board, however when AT&T tested they stated that the when testing they are testing clean to the csu, when dropping they see UAS errors.
  20. quikster2004

    No board

    Im not sure if this is a r or s, how can I tell? I did a disp sys cust and it just states g3 v6.