I have a G3r v9 with an intuity audix release 4.2
If a cell phone user (AT&T service) calls a DID and that person is not on the phone, the call will go to voicemail.
If that person is on the phone, the caller hears line busy and then the call drops.
This seems to only happen with AT&T...
I have a G3R v9. The time on the display phones did not change when DST kicked in Sunday morning. Hitting the date/time button on the phone usually works. I tried unplugging the phone. I tried a busy and release. I also have System Updates Time On Station Displays set to yes in the system...
Changed the codeset from 6 to 0 and it worked like a champ.
I think the default codeset for trunk groups is 6 and I never had to change it.
I didn't have to change the ds1 from 3.1 to speech.
Not yet anyway.
Thanks again ilikeavaya and Yimmer.
I just spoke to my Sprint vendor and he thinks I need to change the codeset on the trunkgroup form from 6 to 0.
He said that their pbx would not allow codeset 6. I ask him about their fax and he thinks that their fax is going to a pots line and not through the pbx. I will make the change first...
I'm having problems dialing a hotel in PR. I can dial their fax number but not their main number. I get a re-order tone from the PBX. I have a G3R v9.
fax number 787-888-6600 working
main number 787-888-6000 not working
I looked in the ars tables to see if it was blocked and I don't see...
I have a company that is going to start transfering calls
from their location to mine. My 800 service provider is
Sprint and they are using AT&T. For the test, I gave them one of my Sprint 800 numbers and they gave me one of their AT&T 800 numbers. The test worked fine except the...
The Alarms have been cleared. Thanks to everyone who lended a hand in solving this problem. This is what I did.
1 I did a reset pnc interchange. The alarms were on pnc-a which was the active pnc. The interchange made the pnc-a the standby pnc and pnc-b the active one.
2 Next I busyout pnc-a...
a-pnc is the stanby pnc which will require me to busy it
out. It might be a good idea for me to do this afterhours.
I have a call center here and at the present time everything seems to work. I just have this alarm I need to get rid of. Thanks to everyone for their input.
Eveything passed but the alarm is still there
test board 1d10 long clear SPE A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01D10 SNC-BD...
I have a G3r with a minor alarm. The alarm look like this
01D04 SNI-PEER n MINOR y 06/01/06:58 00/00/00:00
01D20 SNI-PEER n MINOR y 06/01/06:58 00/00/00:00
01D03 SNI-PEER n MINOR y 06/01/06:58...