I have a hipath 4000
v1 which I suspect that the hd and mo no longer works despite them being active
act-dssm 1 and 6
act-dssm 1 generates a dscr error h 2B and act-dssm 6 generates no media
both disks are mounted on the same board
the system works correctly but I have no access to comwin I...
thinks for your help
the Protocol we use is ECMVA2
IN ALCATEL the Protocol is QSIG-gf
after many attemps the PRA T2 CARD is ok
the probleme is that i have permute pins in the subb 15
of the diun2 card of port 1
now the connection is established but rest the route off calls
how to update...
DISPLAY-REFTA:;
H500: AMO REFTA STARTED
+-------------------------------------------------------------------------+
| R E F E R E N C E C L O C K C I R C U I T S |
+--------------+---------+----------+---+------+------+------+-----+------+
| PEN...
Crc4 is set to N
Hipath is slave and omnipcx is master
The PRA T2 CARD in alcatel show LOS and
RAI error the 30 Chanels indicate HS state
Dis-bssu show activated but not ready
this is the config of diun2 what we done
ADD-BCSU:DIU,1,1,25,"Q2196-X ",0,,,,,1,,,,,A;
DISPLAY-COT:COTNO=120;
H500: AMO COT STARTED
COT: 120 INFO: COT FOR E1
DEVICE: INDEP SOURCE: DB
PARAMETER:
RECALL IF...
We have a hipath 4000 V1 with a DUIN2
Board we want trunking with alcatel omnipcx entreprise T2 interface
Witch protocol must be used and help me Who config diun2 card step by step
Thanks
Dears
Hi,
we have a hipath4000 v1 and we have a problem to acces to mo drive witch contain a backup system
when we try to activate the drive we have this
ACTIVATE-DSSM:UNIT=A1,CNO=6;
H500: AMO DSSM STARTED
F22: DEVICE <:A1H61:> IS NOT ACTIVATED BECAUSE OF DSCR ERROR H'2D
a DDSM display ...
WE HAVE A HIPATH 4000 V1 Connected with analogic line with clip option to post office
how must we configure it to dislpay the incomming call the PO STATION?
yes we have done this with cat tool last five czlls missed. but nothing appears in display
just a question why we must do this with cat tool ? a change setting with sbcsu ( DIGNODIS=N ) can't resolve the probleme ?
we have hipath 4000 v1 which run normally until yesterday .
we have changed the cordless data base (after a breakdown ) with CATtool ver 2.3 and the system run correctly unless the mailphone (missed call) didn't appear in the cordless mobile (SL1).
the parametre DIGNODIS=N in the SBCSU amo is...
hi
i have hipath 4000 v.01 to administrate cordless station , I instal CATtool version 7.0.30
my problem is that this version seem incompatible with my hipath , many amo command don't work (not present
in hard disk ) like amo slcb , zande ...
can any one help me to find another version CATtool...
hi
to generate data from my hipath 4000 to CAT tool we have this erreur: display-zande:typealldata;
M13 VALUE not within admissible range
the amo zande display the same erreur with comwin program
can any one help me ?
until this instant the system is OK CDR's outgoing and are correct
I didn't change the PDC5 board ,all what i do is to invert the mini switch in front of the ADP board to synchrone mode
(V24 interface ) and i return them to asynchrone mode in result CDR trames appears