If you have set up and ACDN as the overflow have you set the MAXP settings and that correctly.
Heres a print of one I use -
REQ prt
TYPE acd
CUST 0
ACDN 6000
TYPE ACD
CUST 0
ACDN 6000
MWC NO
DSAC NO
MAXP 1
SDNB NO
BSCW NO
ISAP NO
AACQ NO
RGAI NO
ACAA NO
FRRT
SRRT
NRRT
FROA NO
CALP POS
ICDD...
We used wired Polycomm's and have never had any issues.
Although as Phnechic says unless the customer asks for a Conference unit we would tell them to use the 2616's.
Gareth
This might be of some use to you or others -
When connecting Superhighway 56 External Modems to Meridian systems the following commands should be entered to ensure correct operation.
· Connect PC to modem with appropriate setting. Eg 9600 baud, 8,1,none
· Enter the following AT string
AT&F...
Telecomwoman, is the wireless headset a bluetooth device, if so would there be any new bluetooth devices added in the area?
If the headset is a Plantronics one would there be any switches on the side that might have got knocked during the move?
Gareth.
Where are you based before I make any suggestions?
SoftEx are good but they are IRE / UK based mainly, not to say they couldn't tweak the call charge info etc.
Gareth
Im not 100% sure if these work on the US Robotics Modems though I think I have used these same commands on them before.
Worth a try if your stuck.
When connecting Superhighway 56 External Modems to Meridian systems the following commands should be entered to ensure correct operation.
·...
Nortel only ever supported the M2250 console when wired on a dedicated 25pr cable. Now as to whether nortel still even support the M2250 console is another question, one some people in Nortel cant agree on either.
I answer to your question, when i'm fitting on a customers site I always request...
In case anyone is interested this problem was only resolved when BT completely rebuilt the lines at the exchange. Once that was complete I reconnected the PBX and everything worked a treat.
G
I have a backup but no I didnt use it. I only programmed the very minimum to get the 12 channels into service.
Yip its was a working 1232 and PRI module from our lab.
Thanks G
I have a version 6 KXTD 1232 with ISDN 30 running on it. all of a sudden on friday the customer complained that there calls were cutting off and there was noise on the lines.
We have since attended site and discovered that the lines drop out after 5-20secs and there is a clicking noise on all...
A SILC card uses just one slot. Although you may be using it a clock for another card (MISP) in that case the MISP would use a slot too.
If you are working on an OPT11c please be aware of this -
Note 1: The NT6D70 SILC card must be installed in the main cabinet
(slots 1 through 9) if it is...