Hi !
I used to do like this :
1. Check AD for users home directory.
2. Enumerate all pipes at that server (WMI against LanmanServer ) where the share is hosted.
3. find user and from any machines that has a pipe.
Best Regards.
NO, have checked NU !
Also checked LC ( all TAB ) and NA.
To Parnum: I know you can't do a FME to an ext. that doesn't exist. But if you do FME over tie-line and then remove that ext. ? Node A has no knowledge about ext in node B
SUSIP and SUDIP shows OK as stated in earlier mess.
Note : it's...
Hi !
No PEN !
Thinking of restarting SLP60 on both sides, but always a lot of traffic. It seems like the user has done a FME to an ext in node A and a FME from that extension in node A back to 36544, and the extension in node A does not longer exist....
Line are probably blocked due to...
36544 is a DTS and SUSIP shows normal IDLE state.
And still there's no problem to dial internally in node B.
I'm not even shure that the call leaves the A node?
I try to send CTDEI on the ext in node A that I'm dialling from, but there isn't enough time to show anything.
Hi !
VERSION=CXP1010105/4/TSWSP02/R3A
I've got a strange error.....
When dialling from node A to node B over private net to ext 36544 I get a "Line Blocked" error ( directly when finished with 5:th digit ). I can without problems dial to any other extension in that series...
Hi !
I think it's something like this :
TRPBI:GRP=12345,DATE=2008-01-xx&&2008-12-31,TIMEI=00-00,TIMEE=24-00;
note: the xx in DATE can only be a date one day ahead or more.
No thats right but you can route it to an abbreviated number, like he tried to do with the 1924 ext.
Operstors can also do the *24*1444*1924# command
The SEL-parameter need to be more than 00 in the last 2 digits though.
Isn't it possible PRE-BC12 to do a *24*......?
I can do it in BC11SP15 but the atleast one of member extensions needs to be a master extension
SPEXI:DIR=XXXX,OPT=M;
ADCOI:ABB=1924,TRA=00123456789,CLASS=0; ( 0&&3 ??? )
Then do the *24*1444*1924# from the XXXX ext.
To cancel : #24*1444# from...
Has IFOR client been installed and configurated propely ?
If you run regsvr32 "c:\Path\to\dll\cclicense.dll "
Do you get the same error ?
There is a compabillity_software_check to dwn-load from M$
Try that on the package.
/ U
It's right foreign domain with no trust or NT4 domain or Exch-5.5 use the SID-property to bind accounts together.
There is a way.....
But you need to know the group-name and the domain.
It's just a little bit tricky but I'll help you on your way
Also a little bit timeconsuming, but...
Try to load an external vbscript to let it run the sleep.
I don't think Wscript.exe is reachable from HTA
<SCRIPT LANGUAGE="VBSCRIPT" SRC="Sleep.vbs">
</SCRIPT>
Then with vbscript you must enumerate a group.members collection and get the SID to compare to the SID of the one your seraching for. Do you have the username ?
Or whats the format of the SID you're searching for ?
Is there a separator, or just some space(s) between the values?
Set fso = CreateObject("Scripting.FilesystemObject")
objFile = fso.OpenTextFile("numbers.log", 1, False)
strFileCont = objFile.ReadAll
objFile.Close
arrFileCont = Split(strFileCont, vbCrLf)
For each strRow in arrFileCont...
You can use a GPO to redirect users to a 'My Doc...' on a network share. Or If you don't use GPO's then use reg.write on your logon-script to set def. folders to a network share
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.